Purpose The aim of this study is to analyze the distribution of visual field (VF) mean defect (MD) in six subgroups of glaucoma patients at baseline and follow-up. Methods We assessed glaucoma patients treated in a Spanish tertiary care setting with a follow-up of at least 10 months. We have included 1036 visual fields and the following glaucoma subtypes: open-Angle Glaucoma (OAG); Angle-Closure Glaucoma (ACG); Congenital Glaucoma (CG); Ocular hypertension (OHT); Pseudoexfoliative Glaucoma (PSXG); Pigmentary Glaucoma (PG). We have calculated the baseline MD and the progression MD. We have stratified the MD progression in slow (MD rate > −0.5 dB/year); moderate (MD rate between −0.5 and −1 dB/year) fast (MD rate between −1 and −2 dB/year) and catastrophic (<−2 dB/year) progression and their glaucoma subtype. Results The glaucoma types with the worse baseline MD were CG and PG. We found significant differences after comparing the baseline MD of CG and OAG, ACG, OHT and between PG and OHT. Concerning the MD progression rate: OAG 73.54% showed slow MD progression rate; 9.85% fast; 7.3% moderate and 9.3% catastrophic. ACG 82.22% slow; 8.89% moderate; 2.22% fast and 6.67% catastrophic. CG 68.83% slow; 9.09% fast; 7.79% moderate and 14.29% catastrophic. OHT 88.6% slow; 6.14% moderate; 4.39% fast and 0.88% catastrophic. PSXG 63.24% slow, 13.24% moderate; 8.8% fast and 14.7% catastrophic. PG 89.29% slow; 3.57% moderate and 7.1% fast. Conclusions The CG requires special attention because of its aggressive presentation and progression.
Purpose: To evaluate the reproducibility of Spectralis spectral domain-OCT segmented ganglion cell layer (GCL) and macular retinal nerve fiber layer (mRNFL) measurements in a healthy children population. Methods: An observational, cross-sectional study was carried out on 79 children to measure the intraobserver reproducibility and the repeatability between a novel and an experienced operator of the segmented macular GCL and mRNFL. Interobserver and intraobserver reproducibility were defined by the intraclass correlation coefficient (ICC) and coefficients of variation (COV). Kruskal–Wallis test was used to determine statistical significance in the COV of three age groups children (younger than 6 years, between 6 and 12, and older than 12 years old). Results: The results from the intraoperator GCL thickness analysis were highly reproducible (COV < 6%) and reliable (ICCs > 0.81). When the measurements were compared between a novel and an experienced examiner lower ICCs and higher COV were found. COVs ranged from 1.85% (total volume area) to 5.57% at the central ETDRS subfield while the ICC vary from 0.632 (outer inferior) to 0.832 (inner inferior). The repeatability and reproducibility of the mRNFL thickness were lower, with ICCs ranging from 0.428 to 0.872 in the interobserver analysis and from 0.897 to 0.346 in the interobserver one. Conclusion: In the present study, we establish substantial reliability of the GCL thickness in children with Spectralis® SD-OCT in all the sectors, albeit lower than the reported in the literature with other SD-OCTs and in adults. The reproducibility and repeatability of the mRNFL were significantly lower. We were unable to find consistent statistical significant differences between the COV of the three age groups.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.