Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2018
DOI: 10.1016/j.jfo.2018.02.015
|View full text |Cite
|
Sign up to set email alerts
|

Comparison of corneal biomechanical properties of patients with dry eye secondary to Sjögren's syndrome and healthy subjects

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

2
3
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 26 publications
2
3
0
Order By: Relevance
“…Conflicting results are available in the literature regarding central corneal thickness in DED. Although few studies showed similar values between DED patients and normal subjects[2427], we found significantly lower values in patients with oGVHD compared to controls, in agreement with others. [3234] The corneal thinning in DED is attributed to the increased osmolarity of the tear film that induces the activation of the inflammatory cascade and stimulate the production of high levels of the cytokine and MMP-9 by the distressed epithelial cells.…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…Conflicting results are available in the literature regarding central corneal thickness in DED. Although few studies showed similar values between DED patients and normal subjects[2427], we found significantly lower values in patients with oGVHD compared to controls, in agreement with others. [3234] The corneal thinning in DED is attributed to the increased osmolarity of the tear film that induces the activation of the inflammatory cascade and stimulate the production of high levels of the cytokine and MMP-9 by the distressed epithelial cells.…”
Section: Discussionsupporting
confidence: 92%
“…To date, few previous studies have investigated corneal biomechanics in patients with DED owing to different etiologies, but not oGVHD, by means of both ORA and CorVis ST.[2427] The former is a non-contact tonometer that provides the measure of two parameters of corneal biomechanics: CRF that reflects the overall resistance of the cornea, and CH that measures the viscoelastic properties of the corneal tissue detecting the changes in the organization of collagen lamellae. CorVis ST is a device that employs an ultrahigh speed Scheimpflug camera to record dynamic deformation of the cornea.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Conflicting results are available in the literature regarding central corneal thickness in DED. Although few studies showed similar values between DED patients and normal subjects[2427], we found significantly lower values in patients with oGVHD compared to controls, in agreement with others. [32–34] The corneal thinning in DED is attributed to the increased osmolarity of the tear film that induces the activation of the inflammatory cascade and stimulate the production of high levels of the cytokine and MMP-9 by the distressed epithelial cells.…”
Section: Discussionsupporting
confidence: 92%
“…CorVis ST is a device that employs an ultrahigh speed Scheimpflug camera to record dynamic deformation of the cornea. Impaired values of corneal biomechanics have been reported in DED patients with and without Sjögren’s syndrome[24–26]; conversely, Firat et al[27] reported no alterations of corneal biomechanical parameters in patients with DED. However, this study did not evaluate comprehensively ocular surface parameters, and did not stratify patients according to the severity of DED.…”
Section: Discussionmentioning
confidence: 99%