Most children and young adults with acquired central diabetes insipidus have abnormal findings on MRI scans of the head, which may change over time, and at least half have anterior pituitary hormone deficiencies during follow-up.
MRI enables morphological and structural changes of CMI to be monitored over time. Follow-up can be extended beyond 2 years, until the CMI has stabilised and subchondral bone marrow oedema has completely resolved. In the single case with a poor CMI outcome, no related direct or indirect signs were identified.
Magnetic resonance arthrography improved the evaluation of implants and facilitated the characterisation of MACI integration with contiguous tissues. The follow-up showed significant changes in MACI, even at 60 months, allowing for useful long-term MR evaluations.
Foreign bodies (FBs) retained in the soft tissues are a common reason for medical consultation, and usually consist of wooden or metal splinters or glass shards. Failure to remove foreign bodies is likely to give rise to acute or late complications, such as allergies, inflammation or infection, that may be severe. The surgical removal of an FB is invasive, costly and technically challenging. The procedure may fail in some cases and carries the risk of complications. Our study describes a technique for the ultrasound-guided removal of an FB, devised from our experience, and demonstrates its advantages over the standard surgical procedure. Sixty-two patients (43 males and 19 females aged from 9 to 65 years, median age 31 years) presented at our institution between October 2005 and June 2008 with suspected foreign bodies retained in the soft tissues of various body districts. Radiographic and/or ultrasound diagnosis was established by a radiologist expert in musculoskeletal sonography. The same radiologist helped by a nurse subsequently undertook the ultrasound-guided removal in the outpatient's clinic according to the technique described in the paper. ATL 5000 and PHILIPS iu22 ultrasound systems were used with high-frequency linear-array probes, sterile material, local anaesthetic (lidocaine 2%), scapels and surgical forceps. Antibiotic prophylaxis with amoxicillin and clavulanic acid were prescribed to all patients for 7 days after the procedure. Ninety-five FBs (39 glass, 35 metal, 17 vegetable, 2 plastic, 2 stone) were successfully removed under ultrasound guidance in all patients and the procedure took between 15 and 30 min. No complications arose either during or after the procedure. Seventy-five skin incisions were made and the wounds closed with Steri-Strips in 73/75 cases, whereas skin sutures were used in 2/75 cases. No complications arose either during or after the procedure. Ultrasound-guided removal of an FB retained in the soft tissues is a good alternative to surgery as is its relatively straightforward, inexpensive, repeatable and carries a low risk of complications. In addition, failure to remove an FB does not preclude traditional surgical removal. The advantages of this real-time procedure and the use of small instruments minimize bleeding time and avoid injury to surrounding structures. Patient compliance is enhanced by the fact that the procedure has little or no aesthetic impact. These encouraging results suggest ultrasound-guided removal as a first-choice procedure for the extraction of foreign bodies.
BackgroundTo evaluate the common sources of diagnostic errors in emergency ultrasonography.MethodsThe authors performed a Medline search using PubMed (National Library of Medicine, Bethesda, Maryland) for original research and review publications examining the common sources of errors in diagnosis with specific reference to emergency ultrasonography. The search design utilized different association of the following terms : (1) emergency ultrasonography, (2) error, (3) malpractice and (4) medical negligence. This review was restricted to human studies and to English-language literature. Four authors reviewed all the titles and subsequent the abstract of 171 articles that appeared appropriate. Other articles were recognized by reviewing the reference lists of significant papers. Finally, the full text of 48 selected articles was reviewed.ResultsSeveral studies indicate that the etiology of error in emergency ultrasonography is multi-factorial. Common sources of error in emergency ultrasonography are: lack of attention to the clinical history and examination, lack of communication with the patient, lack of knowledge of the technical equipment, use of inappropriate probes, inadequate optimization of the images, failure of perception, lack of knowledge of the possible differential diagnoses, over-estimation of one’s own skill, failure to suggest further ultrasound examinations or other imaging techniques.ConclusionsTo reduce errors in interpretation of ultrasonographic findings, the sonographer needs to be aware of the limitations of ultrasonography in the emergency setting, and the similarities in the appearances of various physiological and pathological processes. Adequate clinical informations are essential. Diagnostic errors should be considered not as signs of failure, but as learning opportunities.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.