Digital holography allows the recording, storage and subsequent reconstruction of both amplitude and phase of the light field scattered by an object. This is accomplished by recording interference patterns that preserve the properties of the original object field essential for 3D visualization, the so-called holograms. Digital holography refers to the acquisition of holograms with a digital sensor, typically a CCD or a CMOS camera, and to the reconstruction of the 3D object field using numerical methods. In the current work, the different representations of digital holographic information in the hologram and in the object planes are studied. The coding performance of the different complex field representations, notably Amplitude-Phase and Real-Imaginary, in both the hologram plane and the object plane, is assessed using both computer generated and experimental holograms. The HEVC intra main coding profile is used for the compression of the different representations in both planes, either for experimental holograms or computer generated holograms. The HEVC intra compression in the object plane outperforms encoding in the hologram plane. Furthermore, encoding computer generated holograms in the object plane has a larger benefit than the same encoding over the experimental holograms. This difference was expected, since experimental holograms are affected by a larger negative influence of speckle noise, resulting in a loss of compression efficiency. This work emphasizes the possibility of holographic coding on the object plane, instead of the common encoding in the hologram plane approach. Moreover, this possibility allows direct visualization of the Object Plane Amplitude in a regular 2D display without any transformation methods. The complementary phase information can easily be used to render 3D features such as depth map, multi-view or even holographic interference patterns for further 3D visualization depending on the display technology.
Numerical reconstruction of digital holograms relies on a precise knowledge of the original object position. However, there are a number of relevant applications where this parameter is not known in advance and an efficient autofocusing method is required. This paper addresses the problem of finding optimal focusing methods for use in reconstruction of digital holograms of macroscopic amplitude and phase objects, using digital in-line phase-shifting holography in transmission mode. Fifteen autofocus measures, including spatial-, spectral-, and sparsity-based methods, were evaluated for both synthetic and experimental holograms. The Fresnel transform and the angular spectrum reconstruction methods were compared. Evaluation criteria included unimodality, accuracy, resolution, and computational cost. Autofocusing under angular spectrum propagation tends to perform better with respect to accuracy and unimodality criteria. Phase objects are, generally, more difficult to focus than amplitude objects. The normalized variance, the standard correlation, and the Tenenbaum gradient are the most reliable spatial-based metrics, combining computational efficiency with good accuracy and resolution. A good trade-off between focus performance and computational cost was found for the Fresnelet sparsity method.
Acne is a dermatosis that affects almost 90% of the adolescent population worldwide and its treatment is performed with retinoids, antimicrobials, acids, and topical or systemic antibiotics. Side effects such as skin irritation in addition to microbial resistance to antibiotics are the main side effects found. Phototherapy with blue light is being used as an alternative treatment. Our objective was to analyze the use of blue light to treat inflammatory acne. We conducted a systematic literature review, following the recommendation PRISMA (Preferred Reporting Items for Systematic Reviews and MetaAnalyses), including in the sample randomized clinical trial studies that compared blue light with another intervention as control. The research was carried out in the PUBMED and WEB of SCIENCE databases and the methodological quality of the studies evaluated were made by the Cochrane Collaboration Bias Risk Scale. After the exclusion of duplicates, the titles and abstracts of 81 articles were evaluated, and 50 articles were selected for full reading, including in the review at the end 8 articles. Studies have shown significant improvements in the overall picture of acne. It is concluded that despite the great potential in its use in the treatment of acne, there is a need for more detailed trials on the effect of blue light on the treatment of inflammatory acne.
The paper addresses the joint estimation of backscatter and extinction coe cients from range/time noisy data under a nonlinear stochastic ltering setup. This problem is representative o f m a n y remote sensing applications such a s w eather radar and elastic-backscatter lidar. A Bayesian perspective is adopted. Thus, in addition to the observation mechanism, relating in a probabilistic sense the observed data with the parameters to be estimated, a prior probability density function has to be speci ed. We adopt as prior a causal rst order auto-regressive (AR) Gauss-Markov random eld (GMRF). By using a reduced order state-space representation of the prior, we derive a nonlinear stochastic lter that recursively computes the backscatter and extinction coe cients at each site. A set of experiments based on simulated data illustrates the potential of the proposed approach.
The pseudophakic eye lacks the ability to produce a refractive change in response to object proximity. Thus, individual anatomical features such as the pupil size play an important role in achieving functional vision levels. In this work, the range of pupil sizes at varying object distance was measured in pseudophakic participants. Furthermore, the impact of the measured values on eye optical quality was investigated using a computer simulation model. A binocular eye-tracker was used to measure the participants’ pupil sizes at six object distances, ranging from 0.33 m (i.e., vergence of 3.00 D) to 3.00 m (i.e., vergence of 0.33 D), while observing a Maltese cross with a constant angular size of 1 ∘ . In total, 58 pseudophakic participants were enrolled in this study (age mean ± standard deviation: 70.5 ± 11.3 years). The effects of object distance and age on pupil size variation were investigated using linear mixed effects regression models. Age was found to have a small contribution to individual variability. The mean infinite distance pupil size (intercept) was 4.45 ( 95 % CI: 2.74, 6.17) mm and the mean proximal miosis (slope) was − 0.23 ( 95 % CI: −0.53, 0.08) mm/D. The visual acuity (VA) estimation for a distant object ranged from − 0.1 logMAR (smallest pupil) to 0.04 logMAR (largest pupil) and the near VA ( 0.33 m) when mean proximal miosis was considered ranged from 0.28 logMAR (smallest pupil) to 0.42 logMAR (largest pupil). When mean distance pupil was considered, proximal miosis individual variability produced a variation of 0.04 logMAR for the near object and negligible variation for the distant object. These results support the importance of distance pupil size measurement for the prediction of visual performance in pseudophakia, while suggesting that proximal miosis has a negligible impact in VA variability.
Digital holography is an emerging imaging technique for displaying and sensing three dimensional objects. The perceived image quality of a hologram is frequently corrupted by speckle noise due to coherent illumination. Although several speckle noise reduction methods have been developed so far, there are scarce quality assessment studies to address their performance and they typically focus solely on objective metrics. However, these metrics do not reflect the visual quality perceived by a human observer. In this work, the performance of four speckle reduction algorithms, namely the nonlocal means, the Lee, the Frost and the block matching 3D filters, with varying parameterizations, were subjectively evaluated. The results were ranked with respect to the perceived image quality to obtain the mean opinion scores using pairwise comparison. The correlation between the subjective results and twenty different no-reference objective quality metrics was evaluated. The experiment indicates that block matching 3D and Lee are the preferred filters, depending on hologram characteristics. The best performing objective metrics were identified for each filter.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.