A clinically intuitive physiologic controller is desired to improve the interaction between implantable rotary blood pumps and the cardiovascular system. This controller should restore the Starling mechanism of the heart, thus preventing overpumping and underpumping scenarios plaguing their implementation. A linear Starling-like controller for pump flow which emulated the response of the natural left ventricle (LV) to changes in preload was then derived using pump flow pulsatility as the feedback variable. The controller could also adapt the control line gradient to accommodate longer-term changes in cardiovascular parameters, most importantly LV contractility which caused flow pulsatility to move outside predefined limits. To justify the choice of flow pulsatility, four different pulsatility measures (pump flow, speed, current, and pump head pressure) were investigated as possible surrogates for LV stroke work. Simulations using a validated numerical model were used to examine the relationships between LV stroke work and these measures. All were approximately linear (r(2) (mean ± SD) = 0.989 ± 0.013, n = 30) between the limits of ventricular suction and opening of the aortic valve. After aortic valve opening, the four measures differed greatly in sensitivity to further increases in LV stroke work. Pump flow pulsatility showed more correspondence with changes in LV stroke work before and after opening of the aortic valve and was least affected by changes in the LV and right ventricular (RV) contractility, blood volume, peripheral vascular resistance, and heart rate. The system (flow pulsatility) response to primary changes in pump flow was then demonstrated to be appropriate for stable control of the circulation. As medical practitioners have an instinctive understanding of the Starling curve, which is central to the synchronization of LV and RV outputs, the intuitiveness of the proposed Starling-like controller will promote acceptance and enable rational integration into patterns of hemodynamic management.
A lumped parameter model of human cardiovascular-implantable rotary blood pump (iRBP) interaction has been developed based on experimental data recorded in two healthy pigs with the iRBP in situ. The model includes descriptions of the left and right heart, direct ventricular interaction through the septum and pericardium, the systemic and pulmonary circulations, as well as the iRBP. A subset of parameters was optimized in a least squares sense to faithfully reproduce the experimental measurements (pressures, flows and pump variables). Our fitted model compares favorably with our experimental measurements at a range of pump operating points. Furthermore, we have also suggested the importance of various model features, such as the curvilinearity of the end systolic pressure-volume relationship, the Starling resistance, the suction resistance, the effect of respiration, as well as the influence of the pump inflow and outflow cannulae. Alterations of model parameters were done to investigate the circulatory response to rotary blood pump assistance under heart failure conditions. The present model provides a valuable tool for experiment designs, as well as a platform to aid in the development and evaluation of robust physiological pump control algorithms.
Measurements in phantoms are used to predict temperature changes that would occur in vivo for medical implants due to the radio frequency (RF) field in magnetic resonance imaging (MRI). In this study, the impact of concentration of the gelling agent in a saline-based phantom on the RF-induced temperature rise was measured using an apparatus that accurately reproduces the RF environment present in a 1.5-T whole-body MR system. The temperature was measured using fluoroptic thermometry at the electrode and other sites for a deep brain neurostimulation system. The average power deposition in the 30-kg phantom was about 1.5 W/kg. Four phantom formulations were evaluated, using different concentrations of polyacrylic acid (PAA) added to saline solution, with NaCl concentration adjusted to maintain an electrical conductivity near 0.24 S/m. The greatest temperature rises occurred at the electrode, ranging from 16.2 C for greatest concentration of PAA to 2.9 C for only saline solution. The temperature rise attained the maximal value for sufficient concentration of PAA. Similar behavior was observed in the temperature versus time relationship near a current-carrying resistor, immersed in gel and saline, which was used to model a localized heat source. The temperature rise for insufficient PAA concentration is reduced due to convection of phantom material. In conclusion, an appropriate gelling agent is required to accurately simulate the thermal properties of body tissues for measurements of RF-induced heating with medical implants.
The application of rotary left ventricular (LV) assist devices (LVADs) is expanding from bridge to transplant, to destination and bridge to recovery therapy. Conventional constant speed LVAD controllers do not regulate flow according to preload, and can cause over/underpumping, leading to harmful ventricular suction or pulmonary edema, respectively. We implemented a novel adaptive controller which maintains a linear relationship between mean flow and flow pulsatility to imitate native Starling-like flow regulation which requires only the measurement of VAD flow. In vitro controller evaluation was conducted and the flow sensitivity was compared during simulations of postural change, pulmonary hypertension, and the transition from sleep to wake. The Starling-like controller's flow sensitivity to preload was measured as 0.39 L/min/mm Hg, 10 times greater than constant speed control (0.04 L/min/mm Hg). Constant speed control induced LV suction after sudden simulated pulmonary hypertension, whereas Starling-like control reduced mean flow from 4.14 to 3.58 L/min, maintaining safe support. From simulated sleep to wake, Starling-like control increased flow 2.93 to 4.11 L/min as a response to the increased residual LV pulsatility. The proposed controller has the potential to better match device outflow to patient demand in comparison with conventional constant speed control.
3 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.
In this study, we evaluate a preload-based Starling-like controller for implantable rotary blood pumps (IRBPs) using left ventricular end-diastolic pressure (PLVED) as the feedback variable. Simulations are conducted using a validated mathematical model. The controller emulates the response of the natural left ventricle (LV) to changes in PLVED. We report the performance of the preload-based Starling-like controller in comparison with our recently designed pulsatility controller and constant speed operation. In handling the transition from a baseline state to test states, which include vigorous exercise, blood loss and a major reduction in the LV contractility (LVC), the preload controller outperformed pulsatility control and constant speed operation in all three test scenarios. In exercise, preload-control achieved an increase of 54% in mean pump flow () with minimum loading on the LV, while pulsatility control achieved only a 5% increase in flow and a decrease in mean pump speed. In a hemorrhage scenario, the preload control maintained the greatest safety margin against LV suction. PLVED for the preload controller was 4.9 mmHg, compared with 0.4 mmHg for the pulsatility controller and 0.2 mmHg for the constant speed mode. This was associated with an adequate mean arterial pressure (MAP) of 84 mmHg. In transition to low LVC, for preload control remained constant at 5.22 L/min with a PLVED of 8.0 mmHg. With regards to pulsatility control, fell to the nonviable level of 2.4 L/min with an associated PLVED of 16 mmHg and a MAP of 55 mmHg. Consequently, pulsatility control was deemed inferior to constant speed mode with a PLVED of 11 mmHg and a of 5.13 L/min in low LVC scenario. We conclude that pulsatility control imposes a danger to the patient in the severely reduced LVC scenario, which can be overcome by using a preload-based Starling-like control approach.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.