2010
DOI: 10.1109/tbme.2009.2031629
|View full text |Cite
|
Sign up to set email alerts
|

Parameter-Optimized Model of Cardiovascular–Rotary Blood Pump Interactions

Abstract: A lumped parameter model of human cardiovascular-implantable rotary blood pump (iRBP) interaction has been developed based on experimental data recorded in two healthy pigs with the iRBP in situ. The model includes descriptions of the left and right heart, direct ventricular interaction through the septum and pericardium, the systemic and pulmonary circulations, as well as the iRBP. A subset of parameters was optimized in a least squares sense to faithfully reproduce the experimental measurements (pressures, f… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
67
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(68 citation statements)
references
References 24 publications
1
67
0
Order By: Relevance
“…We consider optimal motor settings for different levels of LV assistance, the effects of the iRBP on the right heart, septum, and pulmonary circulation. Our model results align with those reported in [1]-[2]. Improvement in cardiac output, pulmonary congestion, and heart work are seen with the iRBP.…”
supporting
confidence: 90%
See 1 more Smart Citation
“…We consider optimal motor settings for different levels of LV assistance, the effects of the iRBP on the right heart, septum, and pulmonary circulation. Our model results align with those reported in [1]-[2]. Improvement in cardiac output, pulmonary congestion, and heart work are seen with the iRBP.…”
supporting
confidence: 90%
“…Therefore, modeling has become a key tool in iRBP development. In the second part of this study, we have introduced an iRBP model based on [1]-[2] in the systolic failing heart to study the interactions. We consider optimal motor settings for different levels of LV assistance, the effects of the iRBP on the right heart, septum, and pulmonary circulation.…”
mentioning
confidence: 99%
“…The proposed model was also used to design a control algorithm for continuous and pulsatile flow [2]. A parameter-optimised model for the cardiovascular system assisted by an IRBP was verified in [3].The problem of noninvasive estimation of inlet pressure (P in ) in an IRBP has not been frequently studied, possibly because of its highly variable nature especially during abnormal pumping states such as ventricular collapse where, for example, the inlet pressure (P in ) during the diastolic period in VentrAssist TM (Ventracor Limited, Sydney, Australia) left ventricular assist device (LVAD) may be as low as 2160 mmHg, and varies between +10 mmHg during normal pump operation. During diastole, inlet pressure (P in ) and left ventricular (LV) end diastolic pressure, i.e.…”
mentioning
confidence: 99%
“…The proposed model was also used to design a control algorithm for continuous and pulsatile flow [2]. A parameter-optimised model for the cardiovascular system assisted by an IRBP was verified in [3].…”
mentioning
confidence: 99%
“…CARDIOVASCULAR SYSTEM [60]. 14 FIGURE 1.12: EXAMPLE OF A TIME-VARYING ELASTANCE FUNCTION [63] 15 [63].…”
Section: Figure 111: Example Of a Lumped Parameter Model Of An Lvad mentioning
confidence: 99%