Time-resolved photon emission has been shown to be useful in analyzing clock skews and timing-related defects in flip-chip devices. In practice, time-resolved photon emission using the S-25 Quantar detector cannot be used at long loop lengths (typically >10 μs). This paper discusses a near-infrared (NIR) optimized time-resolved emission system to demonstrate that even with long loop lengths time-resolved photon emission can be extremely useful for defect localization. Specifically, it describes time-resolved photon emission system, and shows how time-resolved photon emission was used to solve two different issues that caused scan fails on silicon-on-insulator devices, and briefly discusses the interpretation of optical waveforms. The two issues are presented as case studies.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.