Several instruments have been used to measure absorbed radiation dose under non-electronic equilibrium conditions, such as in the build-up region or near the interface between two different media, including the surface. Many of these detectors are discussed in this paper. A common method of measuring the absorbed dose distribution and electron contamination in the build-up region of high-energy beams for radiation therapy is by means of parallel-plate ionisation chambers. Thermoluminescent dosimeters (TLDs), diodes and radiographic film have also been used to obtain surface dose measurements. The diamond detector was used recently by the author in an investigation on the effects of beam-modifying devices on skin dose and it is also described in this report.
Objective:
Caesarean section surgical site infection (SSI) is a surgical wound site infection occurring within 30 days of surgery with a reported incidence of 3–15%. This quality improvement (QI) project aimed to reduce caesarean section SSI by 50% in a tertiary maternity center.
Methods:
Using multidisciplinary team approach, the project was designed with evidence-based interventions. The Royal College of Physicians of Ireland/Royal College of Surgeons in Ireland “Preventing Surgical Site Infections Key Recommendations for Practice” guideline was used as standard perioperative care. A care bundle was designed targeting preoperative personal patient preparation, preoperative prophylactic antibiotics, and strict skin preparation technique, all measured using a patient survey. The rate of SSI was followed for 14 months. The Model for Improvement methodology was used to implement change.
Results:
Surgical site infection rate decreased from 6.7% (n = 684 caesarean sections, n = 46 SSI) to 3.45% (n = 3,206 caesarean sections, n = 110 SSI), p = .0006. Reduction occurred in both elective (4.4%–2.7%) and emergency (9.1%–4.1%) caesarean section groups. There was excellent adherence to all three elements of the care bundle. The 50% reduction in caesarean section SSI was sustained over the 14-month period, significantly reducing maternal morbidity.
Conclusions:
The success of this QI project is attributable to frontline ownership and empowerment of patients and staff.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.