Rolling circle amplification (RCA) is an isothermal enzymatic process where a short DNA or RNA primer is amplified to form a long single stranded DNA or RNA using a circular DNA template and special DNA or RNA polymerases. The RCA product is a concatemer containing tens to hundreds of tandem repeats that are complementary to the circular template. The power, simplicity, and versatility of the DNA amplification technique have made it an attractive tool for biomedical research and nanobiotechnology. Traditionally, RCA has been used to develop sensitive diagnostic methods for a variety of targets including nucleic acids (DNA, RNA), small molecules, proteins, and cells. RCA has also attracted significant attention in the field of nanotechnology and nanobiotechnology. The RCA-produced long, single-stranded DNA with repeating units has been used as template for the periodic assembly of nanospecies. Moreover, since RCA products can be tailor-designed by manipulating the circular template, RCA has been employed to generate complex DNA nanostructures such as DNA origami, nanotubes, nanoribbons and DNA based metamaterials. These functional RCA based nanotechnologies have been utilized for biodetection, drug delivery, designing bioelectronic circuits and bioseparation. In this review, we introduce the fundamental engineering principles used to design RCA nanotechnologies, discuss recently developed RCA-based diagnostics and bioanalytical tools, and summarize the use of RCA to construct multivalent molecular scaffolds and nanostructures for applications in biology, diagnostics and therapeutics.
Blood stream infection or sepsis is a major health problem worldwide, with extremely high mortality, which is partly due to the inability to rapidly detect and identify bacteria in the early stages of infection. Here we present a new technology termed ‘Integrated Comprehensive Droplet Digital Detection’ (IC 3D) that can selectively detect bacteria directly from milliliters of diluted blood at single-cell sensitivity in a one-step, culture- and amplification-free process within 1.5–4 h. The IC 3D integrates real-time, DNAzyme-based sensors, droplet microencapsulation and a high-throughput 3D particle counter system. Using Escherichia coli as a target, we demonstrate that the IC 3D can provide absolute quantification of both stock and clinical isolates of E. coli in spiked blood within a broad range of extremely low concentration from 1 to 10,000 bacteria per ml with exceptional robustness and limit of detection in the single digit regime.
Systemically infused mesenchymal stem cells (MSCs) are emerging therapeutics for treating stroke, acute injuries, and inflammatory diseases of the central nervous system (CNS), as well as brain tumors due to their regenerative capacity and ability to secrete trophic, immune modulatory, or other engineered therapeutic factors. It is hypothesized that transplanted MSCs home to and engraft at ischemic and injured sites in the brain in order to exert their therapeutic effects. However, whether MSCs possess the ability to migrate across the blood-brain barrier (BBB) that separates the blood from the brain remains unresolved. This review analyzes recent advances in this area in an attempt to elucidate whether systemically infused MSCs are able to actively transmigrate across the CNS endothelium, particularly under conditions of injury or stroke. Understanding the fate of transplanted MSCs and their CNS trafficking mechanisms will facilitate the development of more effective stem-cell-based therapeutics and drug delivery systems to treat neurological diseases and brain tumors.
Droplet-based microfluidic systems have emerged as a powerful platform for performing high-throughput biological experimentation. In addition, fluorescence polarization has been shown to be effective in reporting a diversity of bimolecular events such as protein-protein, DNA-protein, DNA-DNA, receptor-ligand, enzyme-substrate, and protein-drug interactions. Herein, we report the use of fluorescence polarization for high-throughput protein-protein interaction analysis in a droplet-based microfluidic system. To demonstrate the efficacy of the approach, we investigate the interaction between angiogenin (ANG) and antiangiogenin antibody (anti-ANG Ab) and demonstrate the efficient extraction of dissociation constants (K(D) = 10.4 ± 3.3 nM) within short time periods.
Every little drop: The KD values of angiogenin (ANG) interactions as shown by FRET analysis of thousands of pL‐sized droplets agree with data from bulk‐fluorescence polarization measurements. Importantly, the use of fluorophores does not affect the activity of ANG or the binding of anti‐ANG antibodies to ANG. Such an experimental platform could be applied to the high‐throughput analysis of protein–protein interactions.magnified image
We present a fully integrated droplet-based microfluidic platform for the high-throughput assessment of photodynamic therapy photosensitizer (PDT) efficacy on Escherichia coli. The described platform is able to controllably encapsulate cells and photosensitizer within pL-volume droplets, incubate the droplets over the course of several days, add predetermined concentrations of viability assay agents, expose droplets to varying doses of electromagnetic radiation, and detect both live and dead cells online to score cell viability. The viability of cells after encapsulation and incubation is assessed in a direct fashion, and the viability scoring method is compared to model live/dead systems for calibration. Final results are validated against conventional colony forming unit assays. In addition, we show that the platform can be used to perform concurrent measurements of light and dark toxicity of the PDT agents and that the platform allows simultaneous measurement of experimental parameters that include dark toxicity, photosensitizer concentration, light dose, and oxygenation levels for the development and testing of PDT agents.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.