Sporadic Creutzfeldt-Jakob disease (sCJD) is a rapidly progressive dementia (RPD) that can be difficult to identify ante-mortem, with definitive diagnosis requiring tissue confirmation. We describe the clinical, magnetic resonance imaging (MRI), cerebrospinal fluid (CSF), and electroencephalogram (EEG) measures of a small cohort of 30 patients evaluated for RPD. Clinical and diagnostic measures were cross-sectionally obtained from 17 sCJD patients (15 definite, 2 probable), 13 non-prion rapidly progressive dementia patients (npRPD), and 18 unimpaired controls. In a subset of patients (9 sCJD and 9 npRPD) diffusion tensor imaging (DTI) measures [fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD)] were also obtained for the caudate, corpus callosum, posterior limb of the internal capsule, pulvinar, precuneus, and frontal lobe. Differences among groups were assessed by an analysis of variance. Compared to npRPD individuals, sCJD patients had cerebellar dysfunction, significantly higher CSF tau, “positive” CSF 14-3-3, and hyperintensities on diffusion weighted imaging (DWI) that met previously established imaging criteria for sCJD. EEG changes were similar for the two groups. In addition, sCJD patients had significant decreases in DTI measures (MD, AD, RD but not FA) within the caudate and pulvinar compared to either npRPD patients or unimpaired controls. Our results confirm that CSF abnormalities and MRI (especially DWI) can assist in distinguishing sCJD patients from npRPD patients. Future longitudinal studies using multiple measures (including CSF and MRI) are needed for evaluating pathological changes seen in sCJD patients.
Congenital pulmonary artery anomalies are infrequent but given improved prenatal diagnosis and care, and neonatal surgical advances, over the past two decades are not uncommonly encountered by cardiothoracic imagers. An understanding of their etiology, classifications, associated anomalies, and surgical management can be helpful to avoid under or overdiagnosis. Timely diagnosis assisted by familiarity with imaging findings across modalities and recognition of surgical findings allows for medical management and surgical planning for these patients, with more patients reaching adulthood than ever before.
Conventional contrast-enhanced MR imaging is the current standard technique for the diagnosis and treatment evaluation of gliomas and other brain neoplasms. However, this method is quite limited in its ability to characterize the complex biology of gliomas and so there is a need to develop more quantitative imaging methods. Perfusion and permeability MR imaging are two such techniques that have shown promise in this regard. This review will highlight the underlying principles, applications, and pitfalls of these evolving advanced MRI methods.
on behalf of the PENUT Trial Consortium* Objective To evaluate whether extremely low gestational age neonates (ELGANs) randomized to erythropoietin have better or worse kidney-related outcomes during hospitalization and at 22-26 months of corrected gestational age (cGA) compared with those randomized to placebo.
Study designWe performed an ancillary study to a multicenter double-blind, placebo-controlled randomized clinical trial of erythropoietin in ELGANs.
ResultsThe prevalence of severe (stage 2 or 3) acute kidney injury (AKI) was 18.2%. We did not find a statistically significant difference between those randomized to erythropoietin vs placebo for in-hospital primary (severe AKI) or secondary outcomes (any AKI and serum creatinine/cystatin C values at days 0, 7, 9, and 14). At 22-26 months of cGA, 16% of the cohort had an estimated glomerular filtration rate (eGFR) <90 mL/min/1.73 m 2 , 35.8% had urine albumin/creatinine ratio >30 mg/g, 23% had a systolic blood pressure (SBP) >95th percentile for age, and 40% had a diastolic blood pressure (DBP) >95th percentile for age. SBP >90th percentile occurred less often among recipients of erythropoietin (P < .04). This association remained even after controlling for gestational age, site, and sibship (aOR 0.6; 95% CI 0.39-0.92). We did not find statistically significant differences between treatment groups in eGFR, albumin/creatinine ratio, rates of SBP >95th percentile, or DBP >90th or >95th percentiles at the 2 year follow-up visit.Conclusions ELGANs have high rates of in-hospital AKI and kidney-related problems at 22-26 months of cGA.Recombinant erythropoietin may protect ELGANs against long-term elevated SBP but does not appear to protect from AKI, low eGFR, albuminuria, or elevated DBP at 22-26 months of cGA.
Of the two phantom alignment methods investigated in this study, the use of an anatomical reference point - in this case the geometric centroid of the heart - provided a reliable method for radiation transport simulations of organ dose in pediatric interventional cardiac studies. This alignment method provides the added benefit of requiring no physician input, making retrospective calculations possible. Moving forward, additional anatomical reference methods can be tested to assess the reliability of anatomical reference points beyond cardiac centered procedures.
Rationale and Objectives
To compare quantitative imaging parameter measures from diffusion- and perfusion-weighted imaging magnetic resonance imaging (MRI) sequences in subjects with brain tumors that have been processed with different software platforms.
Materials and Methods
Scans from 20 subjects with primary brain tumors were selected from the Comprehensive Neuro-oncology Data Repository at Washington University School of Medicine (WUSM) and the Swedish Neuroscience Institute. MR images were coregistered, and each subject's data set was processed by three software packages: 1) vendor-specific scanner software, 2) research software developed at WUSM, and 3) a commercially available, Food and Drug Administration–approved, processing platform (Nordic Ice). Regions of interest (ROIs) were chosen within the brain tumor and normal nontumor tissue. The results obtained using these methods were compared.
Results
For diffusion parameters, including mean diffusivity and fractional anisotropy, concordance was high when comparing different processing methods. For perfusion-imaging parameters, a significant variance in cerebral blood volume, cerebral blood flow, and mean transit time (MTT) values was seen when comparing the same raw data processed using different software platforms. Correlation was better with larger ROIs (radii ≥ 5 mm). Greatest variance was observed in MTT.
Conclusions
Diffusion parameter values were consistent across different software processing platforms. Perfusion parameter values were more variable and were influenced by the software used. Variation in the MTT was especially large suggesting that MTT estimation may be unreliable in tumor tissues using current MRI perfusion methods.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.