2018
DOI: 10.1002/mp.13044
|View full text |Cite
|
Sign up to set email alerts
|

Organ doses in pediatric patients undergoing cardiac‐centered fluoroscopically guided interventions: Comparison of three methods for computational phantom alignment

Abstract: Of the two phantom alignment methods investigated in this study, the use of an anatomical reference point - in this case the geometric centroid of the heart - provided a reliable method for radiation transport simulations of organ dose in pediatric interventional cardiac studies. This alignment method provides the added benefit of requiring no physician input, making retrospective calculations possible. Moving forward, additional anatomical reference methods can be tested to assess the reliability of anatomica… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0
2

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 32 publications
0
5
0
2
Order By: Relevance
“…6(a)), as proposed by Omar et al (2016) [69]. The same concept was labelled as the "Table alignment" method by Marshall et al (2018a) [105]. (b) Target-centric refers to a technique where the specific coordinates of the target organ (usually the mid-point of the organ) are measured and used as the reference point, as defined by Omar et al (2016) [69].…”
Section: Patient-phantom and Phantom-beam Alignmentmentioning
confidence: 99%
See 2 more Smart Citations
“…6(a)), as proposed by Omar et al (2016) [69]. The same concept was labelled as the "Table alignment" method by Marshall et al (2018a) [105]. (b) Target-centric refers to a technique where the specific coordinates of the target organ (usually the mid-point of the organ) are measured and used as the reference point, as defined by Omar et al (2016) [69].…”
Section: Patient-phantom and Phantom-beam Alignmentmentioning
confidence: 99%
“…(b) Target-centric refers to a technique where the specific coordinates of the target organ (usually the mid-point of the organ) are measured and used as the reference point, as defined by Omar et al (2016) [69]. The same concept was labelled as "Geometric centre alignment" as Marshall et al (2018a) [105]. The main motivation of this technique is for procedures that are organcentred such as cardiac catheterisation.…”
Section: Patient-phantom and Phantom-beam Alignmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Panorama semelhante é encontrado nos EUA, que apresenta anualmente cerca de 40.000 recém-nascidos com defeitos cardíacos congênitos críticos, que requerem procedimentos intervencionistas no primeiro ano de vida. Estes procedimentos de tratamento normalmente podem evitar que as crianças sejam submetidas à cirurgia convencional (MARSHALL et al, 2018).…”
Section: Capítulo 1: Introdução E Objetivosunclassified
“…Vários estudos foram realizados para investigar as doses para pacientes e, principalmente, para os profissionais que realizam rotineiramente procedimentos de RI. Além dos estudos experimentais, na literatura existe um grande número de artigos envolvendo simulação de Monte Carlo, abordando apenas a dosimetria de pacientes adultos (KIM et al, 2012;SANTOS et al, 2015;SANTOS et al, 2018;WILDGRUBER et al, 2018;HUO et al, 2018;BORREGO et al, 2017;SZUMSKA et al, 2016;KOUKORAVA et al, 2014;JOHNSON et al, 2009;BOZKURT e BOR, 2007;SIISKONEN et al, 2007) e, poucos estudos envolvendo pacientes pediátricos (SAYED et al, 2012;MARSHALL et al, 2018;HARBRON et al, 2016;YAKOUMAKIS et al, 2013;SCHULTZ et al, 2013). Diferentemente desses estudos descritos na literatura, no presente trabalho foram avaliadas as exposições ocupacionais e médicas, considerando o médico e o paciente pediátrico no cenário computacional, usando a simulação de Monte Carlo.…”
Section: Capítulo 1: Introdução E Objetivosunclassified