The TiO2 nanoparticles are electrospun with polyacrylonitrile (PAN) polymer solution onto the discharged battery coal (DBC) electrode and the results are evaluated as a supercapacitor. The morphology and chemical composition of the synthesized TiO2 nanoparticles and PAN+TiO2 nanocomposite fibers were characterized by Scanning electron microscopy, thermogravimetry and FTIR analysis. Supercapacitor measurements and electrochemical characterizations of the electrodes examined by cyclic voltammetry and electrochemical impedance spectroscopy. Electrochemical measurements showed that the best current value was obtained from PAN and TiO2 coated DBC. The performances of both PAN and PAN+TiO2 coated DBC electrodes were investigated as supercapacitors. PAN+TiO2/DBC showed the best specific capacitance value of 156.00 F g−1 and PAN/DBC showed 74.93 F g−1. In addition, PAN+TiO2/DBC exhibited reliable stability performance over 2000.00 cycles.
Graphene sheets and three different graphene-metallic nanocomposites including graphene-copper (graphene-Cu), graphene-nickel (graphene-Ni) and graphene-platinum (graphene-Pt) were prepared and characterized in the first place. Then the electrochemical performances of these nanocomposites were tested in glucose biosensor transducers, which were formed by combining these metallic nanocomposites with glucose oxidase enzyme and glassy carbon paste electrode (GCPE). This is the first work that includes the usage of these graphene-Me nanocomposites as a part of glucose biosensor transducer. Fabricated amperometric biosensors linear ranges were obtained as follow: For the plain graphene, the linear range was found in the concentration range between 50 μM and 800 μM with the RSD (n = 3 for 50 μM glucose) value of 12.86% and LOD value of 7.2 μM. For graphene-Pt modified glucose biosensor, the linear range was between 10 μM and 600 μM with the RSD (n = 3 for 50 μM glucose) value of 3.45% and LOD value of 3.06 μM. In the case of graphene-Ni modified glucose biosensor, the values were 25 μM to 600 μM with the RSD (n = 3 for 50 μM glucose) value of 8.76% and LOD value of 24.71 μM and for graphene-Cu modified glucose biosensor linear range was 25 μM to 400 μM with the RSD (n = 3 for 50 μM glucose) value of 3.93% and LOD value of 2.87 μM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.