PET-CT scanning is an effective tool for detecting asymptomatic disease in patients previously treated for head and neck cancer. Unfortunately, even with early detection of recurrent disease, the mortality rate remains high.
Objective To assess the effect of 3-dimensional (3D)–printed surgical simulators used in an advanced pediatric otolaryngology fellowship preparatory course on trainee education. Study Design Quasi-experimental pre/postsurvey. Setting Multicenter collaborative course conducted at a contract research organization prior to a national conference. Subjects and Methods A 5-station, 7-simulator prep course was piloted for 9 pediatric otolaryngology fellows and 17 otolaryngology senior residents, with simulators for airway graft carving, microtia ear framework carving, and cleft lip/palate repair. Prior to the course, trainees were provided educational materials electronically along with presurveys rating confidence, expertise, and attitude around surgical simulators. In October 2018, surgeons engaged in simulation stations with direction from 2 attending faculty per station, then completed postsurveys for each simulator. Results Statistically significant increases ( P < .05) in self-reported confidence (average, 53%; range, 18%-80%) and expertise (average, 68%; range, 9%-95%) were seen across all simulators, corresponding to medium to large effect sizes as measured by Cohen’s d statistic (0.41-1.71). Positive attitudes around 3D printing in surgical education also demonstrated statistically significant increases (average, 10%; range, 8%-13%). Trainees commented positively on gaining such broad exposure, although consistently indicated a preference for more practice time during the course. Conclusion We demonstrate the benefit of high-fidelity, 3D-printed simulators in exposing trainees to advanced procedures, allowing them hands-on practice in a zero-risk environment. In the future, we hope to refine this course design, develop standardized tools to assess their educational value, and explore opportunities for integration into use in milestone assessment and accreditation.
OBJECTIVEPatients with ventriculoperitoneal (VP) shunts with programmable valves who would benefit from osseointegrated hearing devices (OIHDs) represent a unique population. The aim of this study was to evaluate the magnetic field strengths of 4 OIHDs and their interactions with 5 programmable VP shunt valves.METHODSMagnetic field strength was measured as a function of distance for each hearing device (Cochlear Baha 5, Cochlear Baha BP110, Oticon Ponto Plus Power, and Medtronic Sophono) in the following modes: inactive, active in quiet, and active in 60 decibels of background noise in the sound booth. The hearing devices were introduced to each shunt valve (Aesculap proGAV, Aesculap proGAV 2.0, Codman Hakim, Codman Certas, and Medtronic Strata II) also as a function of distance in these identical 3 settings. Each trial was repeated 5 times. Between each trial, the valves were assessed for a change in setting. Finally, using a skull model, the devices were introduced to each other in standard anatomical locations and the valves were assessed for a change in settings.RESULTSThe maximum magnetic field strengths generated by the Cochlear Baha 5, BP110, and Oticon OIHDs were 1.1, 36.2, and 48.7 gauss (G), respectively. The maximum strength generated by the Sophono device was > 800 G. The magnetic field strength of the hearing devices decreased markedly with increasing distance from the device. The strength of the Sophono's magnetic attachment decreased to 34.8 G at 5 mm. The Codman Hakim, Codman Certas, and Medtronic Strata II valve settings changed when rotating the valves next to the Sophono abutment. No other changes in valve settings occurred in the distance or anatomical models for any other trials.CONCLUSIONSThis is the first study evaluating the interaction between OIHDs and programmable VP shunt valves. The findings suggest that it is safe to use these devices together without having to switch to a nonprogrammable valve or move the shunt valve to a more distant location. Still, care should be taken if the Sophono device is used to ensure that the valve is ≥ 5 mm away from the magnetic attachment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.