The DNA double-strand break (DSB) is the primary lethal lesion after therapeutic radiation. Thus, the development of assays to detect and to quantitate these lesions could have broad preclinical and clinical impact. Phosphorylation of histone H2AX to form γ-H2AX is a known marker for irradiation-induced DNA DSBs. However, the first generation assay involves the use of immunofluorescent staining of γ-H2AX foci. This assay is time consuming, operator dependent and is not scalable for high throughput assay development. Thus, we sought to develop a new assay using a high throughput electrochemiluminescent platform from Mesoscale Discovery Systems to quantify γ-H2AX levels. The results show that our assay utilizes significantly less time and labor, has greater intra-assay reproducibility and has a greater dynamic range of γ-H2AX versus irradiation dose.
PVS/Die and iTero groups offered superior reproduction of the master die in terms of dimensional accuracy, but these differences are likely of little clinical significance.
PurposeAblative bone marrow irradiation is an integral part of hematopoietic stem cell transplantation. These treatment regimens are based on classically held models of radiation dose and the bone marrow response. Flt-3 ligand (FL) has been suggested as a marker of hematopoiesis and bone marrow status but the kinetics of its response to bone marrow irradiation has yet to be fully characterized. In the current study, we examine plasma FL response to total body and partial body irradiation in mice and its relationship with irradiation dose, time of collection and pattern of bone marrow exposure.Materials/MethodsC57BL6 mice received a single whole body or partial body irradiation dose of 1–8 Gy. Plasma was collected by mandibular or cardiac puncture at 24, 48 and 72 hr post-irradiation as well as 1–3 weeks post-irradiation. FL levels were determined via ELISA assay and used to generate two models: a linear regression model and a gated values model correlating plasma FL levels with radiation dose.ResultsAt all doses between 1–8 Gy, plasma FL levels were greater than control and the level of FL increased proportionally to the total body irradiation dose. Differences in FL levels were statistically significant at each dose and at all time points. Partial body irradiation of the trunk areas, encompassing the bulk of the hematopoietically active bone marrow, resulted in significantly increased FL levels over control but irradiation of only the head or extremities did not. FL levels were used to generate a dose prediction model for total body irradiation. In a blinded study, the model differentiated mice into dose received cohorts of 1, 4 or 8 Gy based on plasma FL levels at 24 or 72 hrs post-irradiation.ConclusionOur findings indicate that plasma FL levels might be used as a marker of hematopoietically active bone marrow and radiation exposure in mice.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.