Abstract-A kinematic model is presented based on surface marker placement generating wrist, metacarpal arch, fingers and thumb movements. Standard calculations are used throughout the model and then applied to the specified marker placement. A static trial involving eight unimpaired participants was carried out to assess inter-rater reliability. The standard deviations across the data were comparable to manual goniometers. In addition, a test-retest trial of ten unimpaired participants is also reported to illustrate the variability of movement at the wrist joint, metacarpal arch, and index finger as an example of model output when repeating the same task many times.
The Southampton Hand Assessment Procedure (SHAP) was devised to assess quantitatively the functional range of injured and healthy adult hands. It was designed to be a practical tool for use in a busy clinical setting; thus, it was made simple to use and easy to interpret. This paper describes four examples of its use: before and after a surgical procedure, to observe the impact of an injury, use with prostheses, and during recovery following a fracture. The cases show that the SHAP is capable of monitoring progress and recovery, identifying functional abilities in prosthetic hands and comparing the capabilities of different groups of injuries.
Dynamic movements of the hand, fingers, and thumb are difficult to measure due to the versatility and complexity of movement inherent in function. An innovative approach to measuring hand kinematics is proposed and validated. The proposed system utilizes the Microsoft Kinect and goes beyond gesture recognition to develop a validated measurement technique of finger kinematics. The proposed system adopted landmark definition (validated through ground truth estimation against assessors) and grip classification algorithms, including kinematic definitions (validated against a laboratory-based motion capture system). The results of the validation show 78% accuracy when identifying specific markerless landmarks. In addition, comparative data with a previously validated kinematic measurement technique show accuracy of MCP ± 10° (average absolute error (AAE) = 2.4°), PIP ± 12° (AAE = 4.8°), and DIP ± 11° (AAE = 4.8°). These results are notably better than clinically based alternative manual measurement techniques. The ability to measure hand movements, and therefore functional dexterity, without interfering with underlying composite movements, is the paramount objective to any bespoke measurement system. The proposed system is the first validated markerless measurement system using the Microsoft Kinect that is capable of measuring finger joint kinematics. It is suitable for home-based motion capture for the hand and, therefore, achieves this objective.
We systematically reviewed all the evidence published in the English language on proximal interphalangeal joint (PIPJ) replacement, to determine its effectiveness on the function of the hand and the associated post-operative complications. Original studies were selected if they reported clinical outcome with a minimum of one year's follow-up. Quality was assessed using the Cowley systematic review criteria modified for finger-joint replacements. Of 319 articles identified, only five were adequately reported according to our quality criteria; there were no randomised controlled trials. PIPJ replacements had a substantial effect size on hand pain of -23.2 (95% confidence interval (CI) -27.3 to -19.1) and grip strength 1.2 (95% CI -10.7 to 13.1), and a small effect on range of movement 0.2 (95% CI -0.4 to 0.8). A dorsal approach was most successful. Post-operative loosening occurred in 10% (95% CI 3 to 30) of ceramic and 12.5% (95% CI 7 to 21) of pyrocarbon replacements. Post-operative complications occurred in 27.8% (95% CI 20 to 37). We conclude that the effectiveness of PIPJ replacement has not been established. Small observational case studies and short-term follow-up, together with insufficient reporting of patient data, functional outcomes and complications, limit the value of current evidence. We recommend that a defined core set of patients, surgical and outcome data for this intervention be routinely and systematically collected within the framework of a joint registry.
Given the wide range of methodologies employed, it is not possible to recommend the most appropriate for assessing MCo. Researchers should adopt recognized standards in future work. This is needed before consensus about the role that MCo plays in gait impairment in neurological diseases and its potential as a target for gait rehabilitation can be determined.
The current lack of emphasis on somatosensory rehabilitation may contribute to poor hand recovery in patients with central nervous system pathology. Haptic technologies have the potential to improve sensation and sensory motor integration in neurological conditions An underlying theoretical rationale is provided for the design and clinical use of haptic technologies in neuro-rehabilitation of the hand.
AbstractPurpose. This paper provides rehabilitation professionals and engineers with a theoretical and pragmatic rationale for the inclusion of haptic feedback in the rehabilitation of central nervous system disorders affecting the hand. Method. A narrative review of haptic devices used in sensorimotor hand rehabilitation was undertaken. Presented papers were selected to outline and clarify the underlying somatosensory mechanisms underpinning these technologies and provide exemplars of the evidence to date.Results. Haptic devices provide kinaesthetic and/or tactile stimulation. Kinaesthetic haptics are beginning to be incorporated in central nervous system rehabilitation, however, there has been limited development of tactile haptics. Clinical research in haptic rehabilitation of the hand is embryonic but initial findings indicate potential clinical benefit. Conclusions. Haptic rehabilitation offers the potential to advance sensorimotor hand rehabilitation but both scientific and pragmatic developments are needed to ensure that its potential is realised.
Fast speed and self-perceived balance appear to be important characteristics of ICW at 6 months and may be useful early predictors of the potential for patients to achieve this. Further research is needed to ensure the precision of these functional cut-offs.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.