The Coronavirus disease 2019 (COVID-19) pandemic has caused unprecedented disruption to the normal operation of the healthcare system. On a worldwide scale, hospitals suspended nonurgent surgeries and outpatient visits to downsize clinical loadings to redistribute manpower to counteract the pandemic’s impact. So far, there is no evidence-based guideline defining a clear line between urgent and nonurgent indications of intravitreal injections (IVI). Herein, we aimed to summarize IVI algorithm modifications and discuss the patient prioritization according to medical needs in the hostile environment in the COVID crisis. Assessing current literature, we found that neovascular age-related macular degeneration is considered the utmost priority among conditions that require IVI. Other conditions assigned with a high priority include monocular or quasi-monocular patients (only one eye > 20/40), neovascular glaucoma, and new patients with significant vision loss. Although patients with central retinal vein occlusion and proliferative diabetic retinopathy are not advised to delay treatments, we found no consistent evidence that correlated with a worse outcome. Diabetic macular edema and branch retinal vein occlusion patients undertaking treatment delay should be regularly followed up every 2 to 3 months. Serving as the principle of management behind the algorithm modifications, the reduction of both patient visit and IVI therapy counts should be reckoned together with the risk of permanent visual loss and COVID infection.
SignificanceThis is the first study to validate the repeatability of objective measurements of amplitude of accommodation (AA) using the TONOREF III (NIDEK Co., Ltd., Japan), which can measure the AA in 30 seconds. PurposeTo evaluate the repeatability of objective measurements of AA using the TONOREF III and explored the association between objectively measured AA and factors, including age, sex, spherical equivalent, baseline pupil size and pupil size change during accommodation. MethodsThis cross-sectional study recruited 35 healthy subjects aged 26 to 52 years. The Bland-Altman method and intraclass correlation coefficients (ICCs) were used to assess the repeatability of TONOREF III measurements. The relationships between AA and age, sex, baseline pupil size, changes in pupil size (ΔPS) during accommodation were analyzed using linear regression for univariate and multivariate analysis. ResultsThe mean difference in AA (ΔAA) between two sessions of TONOREF III measurements was 0.23 D (95% CI: -1.07 to +1.53 D), while no significant correlation was found between the mean and ΔAA (p = .14). The ICCs of the TONOREF III was 0.96. Age, sex, and ΔPS during accommodation were significant factors affecting the AA in multivariate analysis. ConclusionsThe repeatability of objective AA measurements using the TONOREF III was good. Measuring AA using the TONOREF TM III in clinical practice is feasible.
Backgrounds: Leber’s hereditary optic neuropathy (LHON) is known as an inherited retinal disorder characterized by the bilateral central vision loss and degeneration of retinal ganglion cells (RGCs). Unaffected LHON carriers are generally asymptomatic, suggesting that certain factors may contribute to the disease manifestations between carriers and patients who carry the same mutated genotypes. Methods: We first aimed to establish the iPSC-differentiated RGCs from the normal healthy subject, the carrier, and the LHON patient and then compared the differential expression profile of circular RNAs (CircRNAs) among RGCs from these donors in vitro. We further overexpressed or knocked down the most upregulated circRNA to examine whether this circRNA contributes to the distinct phenotypic manifestations between the carrier- and patient-derived RGCs. Results: iPSCs were generated from the peripheral blood cells from the healthy subject, the carrier, and the LHON patient and successfully differentiated into RGCs. These RGCs carried equivalent intracellular reactive oxygen species, but only LHON-patient iPSC-derived RGCs exhibited remarkable apoptosis. Next-generation sequencing and quantitative real-time PCR revealed the circRNA hsa_circ_0087207 as the most upregulated circRNA in LHON-patient iPSC-derived RGCs. Overexpression of hsa_circ_0087207 increased the apoptosis in carrier iPSC-derived RGCs, while knockdown of hsa_circ_0087207 attenuated the apoptosis in LHON-patient iPSC-derived RGCs. Predicted by bioinformatics approaches, hsa_circ_0087207 acts as the sponge of miR-665 to induce the expression of a variety of apoptosis-related genes in LHON patient iPSC-derived RGCs. Conclusions: Our data indicated that hsa_circ_0087207 upregulation distinguishes the disease phenotype manifestations between iPSC-derived RGCs generated from the LHON patient and carrier. Targeting the hsa_circ_0087207/miR-665 axis might hold therapeutic promises for the treatment of LHON.
Cataracts, characterized by crystalline lens opacities in human eyes, is the leading cause of blindness globally. Due to its multifactorial complexity, the molecular mechanisms remain poorly understood. Larger cohorts of genome-wide association studies (GWAS) are needed to investigate cataracts’ genetic basis. In this study, a GWAS was performed on the largest Han population to date, analyzing a total of 7079 patients and 13,256 controls from the Taiwan Biobank (TWB) 2.0 cohort. Two cataract-associated SNPs with an adjustment of p < 1 × 10−7 in the older groups and nine SNPs with an adjustment of p < 1 × 10−6 in the younger group were identified. Except for the reported AGMO in animal models, most variations, including rs74774546 in GJA1 and rs237885 in OXTR, were not identified before this study. Furthermore, a polygenic risk score (PRS) was created for the young and old populations to identify high-risk cataract individuals, with areas under the receiver operating curve (AUROCs) of 0.829 and 0.785, respectively, after covariate adjustments. Younger individuals had 17.45 times the risk while older people had 10.97 times the risk when comparing individuals in the highest and lowest PRS quantiles. Validation analysis on an independent TWB1.0 cohort revealed AUROCs of 0.744 and 0.659.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.