Purpose In this study, the insulation fire ratings of lightweight foamed concrete, autoclaved aerated concrete and lightweight aggregate concrete were investigated using finite element modelling. Design/methodology/approach Lightweight aggregate concrete containing various aggregate types, i.e. expanded slag, pumice, expanded clay and expanded shale were studied under standard fire and hydro–carbon fire situations using validated finite element models. Results were used to derive empirical equations for determining the insulation fire ratings of lightweight concrete wall panels. Findings It was observed that autoclaved aerated concrete and foamed lightweight concrete have better insulation fire ratings compared with lightweight aggregate concrete. Depending on the insulation fire rating requirement of 15%–30% of material saving could be achieved when lightweight aggregate concrete wall panels are replaced with the autoclaved aerated or foamed concrete wall panels. Lightweight aggregate concrete fire performance depends on the type of lightweight aggregate. Lightweight concrete with pumice aggregate showed better fire performance among the normal lightweight aggregate concretes. Material saving of 9%–14% could be obtained when pumice aggregate is used as the lightweight aggregate material. Hydrocarbon fire has shown aggressive effect during the first two hours of fire exposure; hence, wall panels with lesser thickness were adversely affected. Originality/value Finding of this study could be used to determine the optimum lightweight concrete wall type and the optimum thickness requirement of the wall panels for a required application.
Lightweight Steel Frames (LSF) in building construction are becoming more popular due to their fast, clean, and flexible constructability. Typical LSF wall panels are made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings. Due to the high thermal conductivity of steel, these LSF components must be well engineered and covered against unintended thermal bridges. Therefore, it is essential to investigate the heat transfer of the LSF wall of different configurations and reduce heat loss through walls by lowering the thermal transmittance, which would ultimately minimise the energy consumption in buildings. The effect of novel thermal insulation material, Vacuum Insulation Panels (VIP), their position on the LSF wall configuration, and Oriented Strand Board (OSB) and plasterboard’s effect on the thermal transmittance of LSF walls were investigated through numerical analysis. A total of 56 wall configurations and 112 finite element models were analysed and compared with the minimum U-value requirements of UK building regulations. Numerical model results exhibited that using plasterboards instead of OSB has no considerable effect on the U-value of the LSF walls. However, 77% (4 times) of U-value reduction was exhibited by introducing the 20 mm VIP. Moreover, the position of the VIP to the U-value of LSF was negligible. Based on the results, optimum LSF wall configurations were proposed by highlighting the construction methods. Additionally, this study, through literature, seeks to identify other areas in which additional research can be conducted to achieve the desired thermal efficiency of buildings using LSF wall systems.
This paper reviews the research advancements and design practices related to the structural web crippling response of lipped Cold-Formed (CF) carbon steel, stainless steel, and aluminium channels with web perforations. The web crippling response differs among each material based on the non-linear stress-strain characteristics and degree of strain hardening. Therefore, the reduction in the web crippling strength of web-perforated CF channel sections made of different materials may not be equivalent. The research activities surrounding the web crippling response of CF channels with and without web openings were reviewed initially. Despite the limited design provisions given in the international specifications for the web crippling design of lipped CF channels with web openings, web crippling studies conducted across the world have developed suitable design equations in the form of reduction factors. Past research studies have substantially captured the web crippling response of carbon steel channels with web openings while that of stainless steel and aluminium are limited, as identified in this paper. Lastly, numerical models were developed for simulating the web crippling behaviour of lipped CF carbon steel, stainless steel, and aluminium channels with web opening and validated with past experimental data, with a view for developing unified design guidelines.
PurposeLight-Gauge Steel Frame (LSF) structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel lipped channel sections negative fire performance, cavity insulation materials are utilized in the LSF configuration to enhance its fire performance. The applicability of lightweight concrete filling as cavity insulation in LSF and its effect on the fire performance of LSF are investigated under realistic design fire exposure, and results are compared with standard fire exposure.Design/methodology/approachA Finite Element model (FEM) was developed to simulate the fire performance of Light Gauge Steel Frame (LSF) walls exposed to realistic design fires. The model was developed utilising Abaqus subroutine to incorporate temperature-dependent properties of the material based on the heating and cooling phases of the realistic design fire temperature. The developed model was validated with the available experimental results and incorporated into a parametric study to evaluate the fire performance of conventional LSF walls compared to LSF walls with lightweight concrete filling under standard and realistic fire exposures.FindingsNovel FEM was developed incorporating temperature and phase (heating and cooling) dependent material properties in simulating the fire performance of structures exposed to realistic design fires. The validated FEM was utilised in the parametric study, and results exhibited that the LSF walls with lightweight concrete have shown better fire performance under insulation and load-bearing criteria in Eurocode parametric fire exposure. Foamed Concrete (FC) of 1,000 kg/m3 density showed best fire performance among lightweight concrete filling, followed by FC of 650 kg/m3 and Autoclaved Aerated Concrete (AAC) 600 kg/m3.Research limitations/implicationsThe developed FEM is capable of investigating the insulation and load-bearing fire ratings of LSF walls. However, with the availability of the elevated temperature mechanical properties of the LSF wall, materials developed model could be further extended to simulate the complete fire behaviour.Practical implicationsLSF structures are popular in building construction due to their lightweight, easy erecting and constructability characteristics. However, due to steel-lipped channel sections negative fire performance, cavity insulation materials are utilised in the LSF configuration to enhance its fire performance. The lightweight concrete filling in LSF is a novel idea that could be practically implemented in the construction, which would enhance both fire performance and the mechanical performance of LSF walls.Originality/valueLimited studies have investigated the fire performance of structural elements exposed to realistic design fires. Numerical models developed in those studies have considered a similar approach as models developed to simulate standard fire exposure. However, due to the heating phase and the cooling phase of the realistic design fires, the numerical model should incorporate both temperature and phase (heating and cooling phase) dependent properties, which was incorporated in this study and validated with the experimental results. Further lightweight concrete filling in LSF is a novel technique in which fire performance was investigated in this study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.