Flight time is the most accurate and frequently used variable when assessing the height of vertical jumps. The purpose of this study was to analyze the validity and reliability of an alternative method (i.e., the HSC-Kinovea method) for measuring the flight time and height of vertical jumping using a low-cost high-speed Casio Exilim FH-25 camera (HSC). To this end, 25 subjects performed a total of 125 vertical jumps on an infrared (IR) platform while simultaneously being recorded with a HSC at 240 fps. Subsequently, 2 observers with no experience in video analysis analyzed the 125 videos independently using the open-license Kinovea 0.8.15 software. The flight times obtained were then converted into vertical jump heights, and the intraclass correlation coefficient (ICC), Bland-Altman plot, and Pearson correlation coefficient were calculated for those variables. The results showed a perfect correlation agreement (ICC = 1, p < 0.0001) between both observers' measurements of flight time and jump height and a highly reliable agreement (ICC = 0.997, p < 0.0001) between the observers' measurements of flight time and jump height using the HSC-Kinovea method and those obtained using the IR system, thus explaining 99.5% (p < 0.0001) of the differences (shared variance) obtained using the IR platform. As a result, besides requiring no previous experience in the use of this technology, the HSC-Kinovea method can be considered to provide similarly valid and reliable measurements of flight time and vertical jump height as more expensive equipment (i.e., IR). As such, coaches from many sports could use the HSC-Kinovea method to measure the flight time and height of their athlete's vertical jumps.
Objectively measured physical activity may influence academic performance during both childhood and adolescence, but this association was negative and very weak. Longitudinal and intervention studies are necessary to further our understanding.
The Assessing Levels of Physical Activity (ALPHA) health-related fitness test battery is a set of reliable, valid, and feasible tests to assess health-related physical fitness in children and in adolescents. The aim of this study was to examine the reliability of this battery in adolescents with Down syndrome (DS). The extended ALPHA health-related fitness test battery was performed twice within 1 month in 17 apparently healthy adolescents, aged 12-18 years, with DS who had an intelligence quotient ≥ 35. Intraclass correlation coefficient (ICC) was used to determinate test-retest reliability, and nonparametric Wilcoxon signed rank test was used to compare mean differences between measurements. With the exception of subscapular skinfold test, which obtained a moderate agreement (ICC = 0.64), all tests had a very high reliability: the 20-m shuttle-run test (ICC = 0.86), the right handgrip strength test (ICC = 0.86), the left handgrip strength test (ICC = 0.86), the standing broad jump test (ICC = 0.85), body mass index (ICC = 0.95), waist circumference (ICC = 0.98), triceps skinfold (ICC = 0.85), and the 4 × 10-m shuttle-run test (ICC = 0.92). There were no significant differences (all p > 0.05) in any of the tests. The ALPHA health-related fitness battery is reliable for measuring health-related components of fitness in adolescents with DS.
Maternal physical activity before and during pregnancy may positively influence youth's academic performance. Continuing maternal physical activity practice during pregnancy may have greater benefits for youth's academic performance.
The aim of this study was to determine the effects of a power training cycle on maximum strength, maximum power, vertical jump height and acceleration in seven high-level 400-meter hurdlers subjected to a specific training program twice a week for 10 weeks. Each training session consisted of five sets of eight jump-squats with the load at which each athlete produced his maximum power. The repetition maximum in the half squat position (RM), maximum power in the jump-squat (W), a squat jump (SJ), countermovement jump (CSJ), and a 30-meter sprint from a standing position were measured before and after the training program using an accelerometer, an infra-red platform and photo-cells. The results indicated the following statistically significant improvements: a 7.9% increase in RM (Z=−2.03, p=0.021, δc=0.39), a 2.3% improvement in SJ (Z=−1.69, p=0.045, δc=0.29), a 1.43% decrease in the 30-meter sprint (Z=−1.70, p=0.044, δc=0.12), and, where maximum power was produced, a change in the RM percentage from 56 to 62% (Z=−1.75, p=0.039, δc=0.54). As such, it can be concluded that strength training with a maximum power load is an effective means of increasing strength and acceleration in high-level hurdlers.
PurposeMonitoring training from a multifactorial point of view is of great importance in elite endurance athletes. This study aims to analyze the relationships between indicators of training load, hormonal status and neuromuscular performance, and to compare these values with competition performance, in elite middle and long-distance runners.MethodFifteen elite middle and long-distance runners (12 men, 3 women; age = 26.3±5.1 yrs) were measured for training volume, training zone and session rate of perceived exertion (RPE) (daily), countermovement jump (CMJ) and salivary free cortisol (weekly) for 39 weeks (i.e., the whole season). Competition performance was also observed throughout the study, registering the season best and worst competitions.ResultsSeason average salivary free cortisol concentrations correlate significantly with CMJ (r = −0.777) and RPE (r = 0.551). Also, weekly averages of CMJ significantly correlates with RPE (r = −0.426), distance run (r = −0.593, p<0.001) and training zone (r = 0.437, p<0.05). Finally, it was found that the CMJ (+8.5%, g = 0.65) and the RPE (−17.6%, g = 0.94) measured the week before the best competition performance of the season were significantly different compared with the measurement conducted the week before the season’s worst competition performance.ConclusionsMonitoring weekly measurements of CMJ and RPE could be recommended to control training process of such athletes in a non-invasive, field-based, systematic way.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.