Aim-To elucidate the diurnal variation in human corneal thickness over a 48 hour period. Method-Changes in central corneal thickness were monitored in eight healthy subjects (four male, four female) aged between 10 and 63 years using an ultrasonic pachymeter. Measurements were made over a 48 hour period-immediately before sleep, immediately upon waking and at 15, 30, 45 minutes, 1, 1.5, 2, 2.5, 3 hours, and at 2 hour intervals thereafter throughout the remainder of each day. Results-The mean corneal thickness for the group (SD) was 546 (14) ptm, with a mean overnight increase of 5.5% (2.90/6) (range 1.9-12.6%) and a maximum diurnal increase of 7.2% (2.8%) (range 2.1-14.3%). Individual differences in the extent of diurnal and overnight variation occurred within the group. For three subjects, the first reading taken on waking was not the highest and corneal thickness continued to increase. Conclusion-These data confirm an increase of corneal thickness during sleep, but also reveal considerable variation during waking hours. Thus, the overnight changes in corneal thickness are not truly representative of diurnal variations in human corneal thickness and, in fact, much greater diurnal variation occurs than the 3.0-4.4% previously reported. (BrJ Ophthalmol 1996;80:1068-1072 Corneal thickness measurements are indicative of the metabolic status of the cornea, as they provide an index of corneal hydration.' Such measurements give valuable information on the physiological status of the cornea and its changes associated with disease,2' trauma,56 and hypoxia.78 The healthy human cornea experiences hypoxia on a daily basis beneath the closed eyelid during sleep.910 The reduction in oxygen levels beneath the closed eyelid is thought to induce anaerobic metabolism, which causes an accumulation of lactate within the stroma which is followed by an osmotic influx of water.7 Other factors could also influence corneal hydration such as the reduced evaporation from the tear film which occurs during the first 2 hours of waking," intraocular pressure which increases rapidly after sleep,'2 and body temperature which changes on a diurnal basis decreasing during night-time sleep and increasing throughout the day.'3 Upon opening the eyelid at waking the corneal thickness is reputed to return rapidly to normal. Thus, corneal thickness changes on a diurnal basis. Such diurnal variations in corneal thickness have been identified in a variety of species, including rabbit,'4 cat,'5 primate,'6 and human.9 17-20It still remains unclear whether overnight changes in human corneal thickness are truly representative of the diurnal variation occurring throughout any 24 hour period or whether the pattern of thickness changes is the same on consecutive days. The aim of this study was to use ultrasonic pachymetry to elucidate the diurnal variation in human corneal thickness in a group of normal healthy human subjects over a 48 hour period. Materials and methods SUBJECTSEight subjects (four male, four female) aged between 10 and 63 years partici...
Methods A prospective study was undertaken on 24 patients who had received full-thickness corneal grafts using corneas stored in organ culture. The donor corneal endothelium was photographed prior to transplantation using light microscopy. Specular microscopy and ultrasonic pachometry were performed at 30 days (± 3 days), 12 weeks (± 1 week), 26 weeks (± 2 weeks) and 52 weeks (± 4 weeks) following corneal transplantation. The following cell parameters were measured: density, area, coefficient of variation (CV) for area, perimeter, diameter, form factor and corneal thickness.Results One year after corneal transplantation there was a statistically significant decrease in endothelial cell density (-39.4%), and a statistically significant increase in endothelial cell area (+94.4%), perimeter (+36.1%), diameter (+57.1%) and form factor (+5.8%).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.