AlCrN/TiSi, AlCrN/TiCrSiN and AlCrN/AlCrN + CrN coatings were deposited on Inconel 718 alloy by physical vapour deposition (PVD). The corrosion behaviour of uncoated and coated specimens was evaluated using electrochemical impedance spectroscopy (EIS) at open circuit potential in a 3.5 wt.% NaCl and 2 wt.% H2SO4 solutions. The EIS data acquired were curve fitted and analysed by equivalent circuit models to calculate the pore resistance, the charge transfer resistance and the capacitance. The Nyquist diagrams of all systems showed one part of the semicircle which could relate that reaction is a one step process, except for the AlCrN/TiCrSiN and AlCrN/AlCrN + CrN coatings in H2SO4 solution, for which two semicircles related to active corrosion in substrate alloy were found. However, from the Bode plots, it was possible to identify two the time constants for all systems exposed to NaCl and H2SO4 solutions. According to electrochemical results, the corrosion resistance of the AlCrN/TiSiN coating was better in the NaCl solution, whereas the AlCrN/AlCrN + CrN coating show better performance in the Sulphuric Acid solutions.
Advanced high-strength steels (AHSS), are commonly used in the manufacture of car bodies, as well as in front and rear rails, and safety posts. These components can be exposed to corrosive environments for instance, in countries where de-icing salts are used. In this work, the corrosion behavior of four AHSS steels with dual-phase [ferrite-martensite (DP) and ferrite-bainite (FB)] steels were studied by means of electrochemical noise (EN) measurements according to the ASTM G199-09 standard in NaCl, CaCl2 and MgCl2 aqueous solutions at room temperature. The direct current (DC) trend data from EN were removed by a polynomial method of statistical and spectral analysis. According to the noise resistance (Rn) values obtained for the DP and FB dual-phase steels, both the martensite/bainite content and morphology of the phase constituents have an important effect on the corrosion behavior of these steels. The L.I. (localization index) (0.00054 to 0.15431), skewness (−6.18 to 7.35) and kurtosis (high values 37.15, 74.84 and 106.52) were calculated. In general, the results indicated that the main corrosion process is related to uniform corrosion. Corrosion behavior of AHSS steels exposed in NaCl solution could be related to the morphology of the phase constituents exposed in NaCl, CaCl2 and MgCl2 solutions.
Titanium alloys are used in different industries like biomedical, aerospace, aeronautic, chemical, and naval. Those industries have high requirements with few damage tolerances. Therefore, they are necessary to use materials that present fatigue, mechanical, and corrosion resistance. Although Ti-alloys are material with high performance, they are exposed to corrosion in marine and industrial environments. This research shows the corrosion behavior of three titanium alloys, specifically Ti CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V. Alloys were exposed on two electrolytes to a 3.5 wt % H2SO4 and NaCl solutions at room temperature using cyclic potentiodynamic polarization (CPP) and electrochemical noise (EN) according to ASTM G61 and ASTM G199 standards. CPP technique was employed to obtain electrochemical parameters as the passivation range (PR), corrosion type, passive layer persistence, corrosion potential (Ecorr), and corrosion rate. EN was analyzed by power spectral density (PSD) in voltage. Results obtained revealed pseudopassivation in CPP and PSD exposed on NaCl for Ti-6Al-2Sn-4Zr-2Mo, indicating instability and corrosion rate lower. However, Ti-6Al-4V presented the highest corrosion rate in both electrolytes. Ti-6Al-2Sn-4Zr-2Mo revealed pseudopassivation in CPP and PSD in NaCl, indicating a passive layer unstable. However, the corrosion rate was lower in both solutions.
Nickel or Cobalt-based superalloys represent an important class of engineering materials, finding widespread application in critical components within the gas turbine engines used for jet propulsion and electricity generation. This research aimed at the frequency analysis of transients in electrochemical noise of Waspaloy and Ultimet superalloys, immersed in 3.5 wt.% in H2SO4 and NaCl solutions at two different temperatures, 25 and 60 °C. Localized corrosion behavior of superalloys was assessed using the electrochemical noise technique (EN) according to ASTM-G199 standard. Three different statistical methods filtered the EN signal, and the polynomial method was employed to obtain the noise resistance (Rn), the localization index (LI), skew and kurtosis, and the power spectral density analysis (PSD). Results indicate that the current and potential noise transients have a better behavior with better clarity when a polynomial is used to show a localized corrosion kurtosis for both superalloys.
The useful life of superheaters and reheaters of power stations which use heavy fuel oil is shortened and their continuous service is inhibited by corrosion (fireside) and creep-type problems. The increase of corrosion attack on boilers is caused by the presence of fuel ash deposits containing mainly vanadium, sodium, and sulfur which form low-melting-point compounds. The tubes are exposed to the action of high stresses and high temperatures, producing the so-called "creep damage." In this work, two kinds of results are reported: lab and field studies using a 2.25Cr-1Mo steel. The laboratory work was in turn divided into two parts. In the first, the steel was exposed to the action of natural ash deposits in oxidant atmospheres at 600 °C for 24 h. In the second part, tensile specimens were creep tested in Na 2 SO 4 , V 2 O 5 , and their mixture over a temperature range of 580 to 620 °C. In the field work, components of a power station were coated with different types of nickel-and iron-base coatings containing chromium, Fe-Cr, and Fe-Si using the powder flame spraying technique. After testing, the coated tubes were analyzed using electron microscopy. The results showed that all the coating systems had good corrosion resistance, especially those containing silicon or chromium.
Corrosion of steel reinforcement is the major factor that limits the durability and serviceability performance of reinforced concrete structures. Impressed current cathodic protection (ICCP) is a widely used method to protect steel reinforcements against corrosion. This research aimed to study the effect of cathodic protection on reinforced concrete with fly ash using electrochemical noise (EN). Two types of reinforced concrete mixtures were manufactured; 100% Ordinary Portland Cement (OCP) and replacing 15% of cement using fly ash (OCPFA). The specimens were under-designed protected conditions (−1000 ≤ E ≤ −850 mV vs. Ag/AgCl) and cathodic overprotection (E < −1000 mV vs. Ag/AgCl) by impressed current, and specimens concrete were immersed in a 3.5 wt.% sodium chloride (NaCl) Solution. The analysis of electrochemical noise-time series showed that the mixtures microstructure influenced the corrosion process. Transients of uniform corrosion were observed in the specimens elaborated with (OPC), unlike those elaborated with (OPCFA). This phenomenon marked the difference in the concrete matrix’s hydration products, preventing Cl− ions flow and showing passive current and potential transients in most specimens.
In the present investigation, the protector against sulfate corrosion of reinforcing steel AISI 1018, which provides the Eco-friendly Concrete system CPC-SCBA-SF, was evaluated. This system was made with CPC-SCBA-SF cementitious materials, in percentages of 90-5-5 and 80-10-10 respectively, with exposure of the concrete specimens to a 3.5% MgSO4 solution, an experimental arrangement that simulates the foundations of Civil Works such as bridges, buildings, pavements, etc.; in soils contaminated with sulfates. The design of the concrete mixtures was in accordance with the ACI 211.1 method. The behavior of the corrosion potential Ecorr and the corrosion rate (icorr) of the AISI 1018 steel embedded in Conventional Concrete (CC) and in the EC were evaluated during a period of 180 days of exposure to an aggressive environment. The Ecorr values indicate between a 10% risk of corrosion and uncertainty, according to the ASTM C-876-15 standard, but the icorr indicates a negligible level of corrosion but with a tendency towards the activation of the system, with the eco-friendly concrete EC-20 having the best performance.
The author wishes to make the following correction to this paper [...]
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.