The unique bony architecture of the proximal ulna presents particular difficulties for the implants used in fracture fixation and arthroplasty of the elbow. Knowing the detailed anatomy of the variations of proximal ulna will guide the surgeon to obtain a more reliable length of the olecranon and to offer a safe place for Kirschner wire replacement concerning humero-ulnar joint functionality. In this study, PUTA was also defined. The angle determines the rotation of the proximal ulna and it has a great importance for the movements of the joint. The measured angulations will help the surgeon to design the proper prosthesis for the maintenance of the functions of the elbow joint.
Variations of the sutures and sutural bones can be easily misdiagnosed with the fractures of related bony regions in unconscious patients with multiple traumas. During surgical interventions in these type of patients; surgeons must take this fact into consideration in order to make differential diagnosis of fractures and intersutural bone variations.
In this study we aimed to compare the findings of coronary dual-source computed tomography angiography of myocardial bridges with cadaveric dissections. Forty-one isolated, non-damaged fresh sheep hearts were used in this study. Myocardial bridges of the anterior interventricular branch of the left coronary artery were demonstrated and analyzed by a coronary dual-source computed tomography angiography. Dissections along the left anterior interventricular branch of the left coronary artery were performed by using Zeiss OPMI pico microscope and the length of the bridges were measured. The depths of the myocardial bridges were measured from the stained sections by using the light microscope (Leica DM 6000B). MBs were found in all 41 hearts (100%) during dissections. Dual-source computed tomography angiography successfully detected 87.8% (36 of the 41 hearts) of the myocardial bridges measured on left anterior interventricular branch of left coronary artery. The lengths of the myocardial bridges were found 5-40 and 8-50 mm with dissection and dual-source computed tomography angiography, respectively. And the depths were found 0.7-4.5 mm by dual-source computed tomography angiography and 0.745-4.632 mm morphologically. Comparison of the mean values of the lengths showed statistically significantly higher values (22.0 ± 8.5, 17.7 ± 7.7 mm, p = 0.003) for the dissections. Radiological assessment also effectively discriminated complete bridges from incomplete ones. Our study showed that coronary computed tomography angiography is reliable in evaluating the presence and depth of myocardial bridges.
Background/aim: The localization of the standard posterior portal of shoulder arthroscopy and landmarks mentioned in the literature are unclear. The purpose of this prospective cadaveric study was to determine the localization of the standard posterior portal and its distance to the neural structures.
Materials and methods:One fresh frozen and 10 formalin-fixed adult cadaveric shoulders were dissected. In the beach chair position, a 5-mm trocar was placed anteroposteriorly from the superior edge of the subscapularis muscle, superior to the tip of the coracoid process and tangent to the glenoid. The relevant distances of the posterior exit point were measured.Results: In all specimens, the exit point was a triangular fibrous area, between the posterior and lateral parts of the deltoid. Medial and inferior distances of the trocar to the posterolateral tip of the acromion were 1.88 ± 0.53 cm and 1.35 ± 0.34 cm and distances to the axillary and suprascapular nerves were 4.54 ± 1.08 cm and 2.54 ± 0.85 cm, respectively.
Conclusion:The most important finding of this study was the superficial localization of the soft spot between the posterior and lateral parts of deltoid.
When applying the modified tension band wiring technique to prevent articular penetration, K-wires should be inserted in the first 5 mm from dorsal cortex of the olecranon process at a maximum angle of 20°. Moreover, if the wires are required to be inserted more anteriorly because of the anatomical configuration of the fracture, they should be inserted at a shallow angle in the sagittal plane in relation to the proximal cortex of the ulna.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.