The presence of donor‐specific anti‐HLA antibodies (DSAs) is associated with increased risk of graft failure after kidney transplant. We hypothesized that DSAs against HLA class I, class II, or both classes indicate a different risk for graft loss between deceased and living donor transplant. In this study, we investigated the impact of pretransplant DSAs, by using single antigen bead assays, on long‐term graft survival in 3237 deceased and 1487 living donor kidney transplants with a negative complement‐dependent crossmatch. In living donor transplants, we found a limited effect on graft survival of DSAs against class I or II antigens after transplant. Class I and II DSAs combined resulted in decreased 10‐year graft survival (84% to 75%). In contrast, after deceased donor transplant, patients with class I or class II DSAs had a 10‐year graft survival of 59% and 60%, respectively, both significantly lower than the survival for patients without DSAs (76%). The combination of class I and II DSAs resulted in a 10‐year survival of 54% in deceased donor transplants. In conclusion, class I and II DSAs are a clear risk factor for graft loss in deceased donor transplants, while in living donor transplants, class I and II DSAs seem to be associated with an increased risk for graft failure, but this could not be assessed due to their low prevalence.
Shaikh A. Nurmohamed 11 | Neubury M. Lardy 12 | Wendy Swelsen 12 | Karlijn A. M. I. van der Pant 2 | Neelke C. van der Weerd 2 | Ineke J. M. ten Berge 2 |This is an open access article under the terms of the Creat ive Commo ns Attri bution-NonCo mmercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
Whereas regular allocation avoids unacceptable mismatches on the donor organ, allocation to highly sensitized patients within the Eurotransplant Acceptable Mismatch (AM) program is based on the patient's HLA phenotype plus acceptable antigens. These are HLA antigens to which the patient never made antibodies, as determined by extensive laboratory testing. AM patients have superior long‐term graft survival compared with highly sensitized patients in regular allocation. Here, we questioned whether the AM program also results in lower rejection rates. From the PROCARE cohort, consisting of all Dutch kidney transplants in 1995‐2005, we selected deceased donor single transplants with a minimum of 1 HLA mismatch and determined the cumulative 6‐month rejection incidence for patients in AM or regular allocation. Additionally, we determined the effect of minimal matching criteria of 1 HLA‐B plus 1 HLA‐DR, or 2 HLA‐DR antigens on rejection incidence. AM patients showed significantly lower rejection rates than highly immunized patients in regular allocation, comparable to nonsensitized patients, independent of other risk factors for rejection. In contrast to highly sensitized patients in regular allocation, minimal matching criteria did not affect rejection rates in AM patients. Allocation based on acceptable antigens leads to relatively low‐risk transplants for highly sensitized patients with rejection rates similar to those of nonimmunized individuals.
The best treatment for patients with end-stage renal disease is kidney transplantation. Although graft survival rates have improved in the last decades, patients still may lose their grafts partly due to the detrimental effects of donor-specific antibodies (DSA) against human leukocyte antigens (HLA) and to a lesser extent also by antibodies directed against non-HLA antigens expressed on the donor endothelium. Assays to detect anti-HLA antibodies are already in use for many years and have been proven useful for transplant risk stratification. Currently, there is a need for assays to additionally detect multiple non-HLA antibodies simultaneously in order to study their clinical relevance in solid organ transplantation. This study describes the development, technical details and validation of a high-throughput multiplex assay for the detection of antibodies against 14 non-HLA antigens coupled directly to MagPlex microspheres or indirectly via a HaloTag. The non-HLA antigens have been selected based on a literature search in patients with kidney disease or following transplantation. Due to the flexibility of the assay, this approach can be used to include alternative antigens and can also be used for screening of other organ transplant recipients, such as heart and lung.
With respect to pretransplant risk stratification, we propose a SBTR-6 (using the bead of the same HLA-locus with lowest MFI as background) cut-off of 15 combined with an MFI cut-off of 500, resulting in 8% and 21% lower 1- and 10-years graft survival, respectively, for 8% DSA positive transplants.
Complement-fixing antibodies against donor HLA are considered a contraindication for kidney transplant. A modification of the IgG single-antigen bead (SAB) assay allows detection of anti-HLA antibodies that bind C3d. Because early humoral graft rejection is considered to be complement mediated, this SAB-based technique may provide a valuable tool in the pretransplant risk stratification of kidney transplant recipients. Previously, we established that pretransplant donor-specific anti-HLA antibodies (DSAs) are associated with increased risk for long-term graft failure in complement-dependent cytotoxicity crossmatch-negative transplants. In this study, we further characterized the DSA-positive serum samples using the C3d SAB assay. Among 567 pretransplant DSA-positive serum samples, 97 (17%) contained at least one C3d-fixing DSA, whereas 470 (83%) had non-C3d-fixing DSA. At 10 years after transplant, patients with C3d-fixing antibodies had a death-censored, covariate-adjusted graft survival of 60%, whereas patients with non-C3d-fixing DSA had a graft survival of 64% (hazard ratio, 1.02; 95% confidence interval, 0.70 to 1.48 for C3d-fixing DSA compared with non-C3d-fixing DSA; =0.93). Patients without DSA had a 10-year graft survival of 78%. The C3d-fixing ability of pretransplant DSA is not associated with increased risk for graft failure.
A paired kidney analysis on the impact of pre-transplant anti-HLA antibodies on graft survival Abstract Background Pretransplant donor-specific anti-HLA antibodies (DSA) are associated with impaired kidney graft survival, while the clinical relevance of non-donor specific anti-HLA antibodies (nDSA) is more controversial. The aim of the present paired kidney graft study was to compare the clinical relevance of DSA and nDSA. MethodsTo eliminate donor and era-dependent factors, a post-hoc paired kidney graft analysis was performed as part of a Dutch multicentre study evaluating all transplantations between 1995-2005 with available pretransplant serum samples. Anti-HLA antibodies were detected with a luminex single antigen bead assay. ResultsAmong 3237 deceased donor transplantations, we identified 115 recipient pairs receiving a kidney from the same donor with one recipient being DSA positive and the other without anti-HLA antibodies.Patients with pretransplant DSA had a significantly lower 10-year death censored graft survival (55% vs. 82%, p=0.0001). Among 192 pairs with one recipient nDSA positive against either class I or II and the other without anti-HLA antibodies, graft survival did not significantly differ (74% vs. 77%, p=0.79).Only in patients with both nDSA class I and II there was a trend towards a lower graft survival (58%, p=0.06). Lastly, in a small group of 42 recipient pairs 10-year graft survival in recipients with DSA was 49% compared to 68% in recipients with nDSA (p=0.11). ConclusionThis paired kidney analysis confirms that the presence of pretransplant DSA in deceased donor transplantations is a risk marker for graft loss, whereas nDSA in general are not associated with a lower graft survival. Subgroup analysis indicated that only in broadly sensitized patients with nDSA against class I and II, nDSA may be a risk marker for graft loss in the long term.
Background Few studies have evaluated the effect of different immunosuppressive strategies on long-term kidney transplant outcomes. Moreover, as they were usually based on historical data, it was not possible to account for the presence of pretransplant donor-specific human-leukocyte antigen antibodies (DSA), a currently recognized risk marker for impaired graft survival. The aim of this study was to evaluate to what extent frequently used initial immunosuppressive therapies increase graft survival in immunological low-risk patients. Methods We performed an analysis on the PROCARE cohort, a Dutch multicentre study including all transplantations performed in the Netherlands between 1995 and 2005 with available pretransplant serum (n = 4724). All sera were assessed for the presence of DSA by a luminex single-antigen bead assay. Patients with a previous kidney transplantation, pretransplant DSA or receiving induction therapy were excluded from the analysis. Results Three regimes were used in over 200 patients: cyclosporine (CsA)/prednisolone (Pred) (n = 542), CsA/mycophenolate mofetil (MMF)/Pred (n = 857) and tacrolimus (TAC)/MMF/Pred (n = 811). Covariate-adjusted analysis revealed no significant differences in 10-year death-censored graft survival between patients on TAC/MMF/Pred therapy (79%) compared with patients on CsA/MMF/Pred (82%, P = 0.88) or CsA/Pred (79%, P = 0.21). However, 1-year rejection-free survival censored for death and failure unrelated to rejection was significantly higher for TAC/MMF/Pred (81%) when compared with CsA/MMF/Pred (67%, P < 0.0001) and CsA/Pred (64%, P < 0.0001). Conclusion These results suggest that in immunological low-risk patients excellent long-term kidney graft survival can be achieved irrespective of the type of initial immunosuppressive therapy (CsA or TAC; with or without MMF), despite differences in 1-year rejection-free survival.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.