The centrifugal VAD successfully supported pediatric patients awaiting heart transplantation. The modified recirculation shunt facilitated the successful support of patients in whom optimal flows were substantially lower than those recommended by the manufacturer. The design allows placement of an in-line oxygenator. Compared with pulsatile devices, use of this VAD was associated with a trend toward decreased mortality associated with VAD use.
A continuous flow extracorporeal ventricular assist device (VAD) was modified to support functionally univentricular infants and children awaiting heart transplantation. A centrifugal VAD, designed to flow from 1.5 to 8 L/min, was used as a bridge-to-transplant in four patients with functionally univentricular circulation. A variable restrictive recirculation shunt permitted lower flow ranges in small patients. In hypoxic patients, an oxygenator was incorporated into the circuit. From 2012 to 2015, the modified VAD was placed in four patients with Glenn physiology. Age ranged from 0.97 to 6.98 years (median = 2.2 yrs). Body surface area ranged from 0.41 to 0.84 m (median = 0.54 m ). One patient was on extracorporeal membrane oxygenation prior to VAD. A recirculation shunt was used in three patients. Three patients required temporary use of an oxygenator for 4, 10, and 27 days. Median time on the VAD was 32.3 days (range = 23-43 days). A decrease in the cavopulmonary pressure was noted in all patients, as was a fall in the B-type natriuretic peptide. Three patients survived transplant and were discharged at 28-82 days post-transplantation. One patient died after 35 days of support. Two patients experienced major bleeding events. Two patients experienced cerebrovascular accidents, one major and one minor. The centrifugal VAD successfully supported palliated functionally univentricular patients awaiting heart transplantation. The modified recirculation shunt facilitated the successful support of patients in whom optimal flows were substantially lower than that recommended by the manufacturer. The continuous-flow VAD effectively decompressed the cavopulmonary system. The design allowed placement of an in-line oxygenator in hypoxic patients. Further investigation is required to decrease the thromboembolic events, and associated morbidity, in patients supported with this device.
A nine-year-old girl ( 23 kg) was successfully bridged to heart transplantation with the TandemHeart(®) centrifugal pump for 10 days. Although this cardiac assist device has been used in adults for short-term mechanical support, its use in the pediatric population has not been widely reported. The TandemHeart(®) was easy to implant, achieved appropriate flows in this pediatric patient, and allowed for extubation and ambulation while awaiting a donor heart.
Hypoplastic left heart syndrome (HLHS) is a rare and severe congenital cardiac defect. Approximately 1000 infants are born with HLHS in the United States every year. Healthcare collaboratives over the last decade have focused on sharing patient experiences and techniques in an effort to improve outcomes. In 2010, cardiologists and patient families joined together to improve the care of HLHS patients by forming the National Pediatric Cardiology Quality Improvement Collaborative (NPC-QIC). Sixty-six of the approximately 110 institutions caring for patients with HLHS in the United States and Canada are now members of NPC-QIC. In 2017, cardiovascular perfusionists joined the collaborative as another specialty involved in the care of HLHS patients. Perfusionists and cardiac surgeons developed the collaborative's first conduct of perfusion survey for the Norwood Stage 1 procedure, specifically targeting the provision of cardiopulmonary bypass for patients with HLHS. This manuscript discusses the results of this survey, unveiling a significant variance in the conduct of perfusion for this patient population.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.