2014
DOI: 10.1016/j.athoracsur.2014.05.093
|View full text |Cite
|
Sign up to set email alerts
|

Modified TandemHeart Ventricular Assist Device for Infant and Pediatric Circulatory Support

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
20
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
4
2
1

Relationship

2
5

Authors

Journals

citations
Cited by 21 publications
(20 citation statements)
references
References 7 publications
0
20
0
Order By: Relevance
“…It is recommended by the manufacturer that the flow rate remain at greater than 1.5 L/min to decrease the risk of thrombosis. Our first modification of the VAD circuit was the addition of a variable restrictive recirculation shunt (Fig 1), enabling lower patient flow rates [6]. Our second modification has been to place an oxygenator into the circuit for hypoxic patients.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…It is recommended by the manufacturer that the flow rate remain at greater than 1.5 L/min to decrease the risk of thrombosis. Our first modification of the VAD circuit was the addition of a variable restrictive recirculation shunt (Fig 1), enabling lower patient flow rates [6]. Our second modification has been to place an oxygenator into the circuit for hypoxic patients.…”
Section: Methodsmentioning
confidence: 99%
“…Our second modification has been to place an oxygenator into the circuit for hypoxic patients. Our surgical technique of VAD implantation has been previously described [5,6]. On cardiopulmonary bypass, the dome of the left atrium is cannulated with a standard right-angle venous cannula.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…It has achieved the CE Mark in Europe for use up to 30 days. Although for adults, the system has been modified to be used in children . While it is designed for LV support, it has also been applied in right‐sided and biventricular support cases .…”
Section: Clinically Used Devicesmentioning
confidence: 99%
“…Advantages of the TandemHeart VAD include the simplicity of implantation and de‐airing, and reduced risk of blood trauma, hemolysis, and bleeding . Later, we described a modification of the VAD circuit with a variable restrictive recirculation shunt to permit lower flow ranges in small pediatric patients . Recently, we presented our excellent results using this device in 13 children, with a low morbidity and 100% survival rate.…”
mentioning
confidence: 99%