Achieving a stable bone-implant interface is an important factor in the long-term outcome of joint arthroplasty. In this study, we employed an ovine bicortical model to compare the bone-healing response to five different surfaces on titanium alloy implants: grit blasted (GB), grit blasted plus hydroxyapatite (50 microm thick) coating (GBHA), Porocoat(R) (PC), Porocoat(R) with HA (PCHA) and smooth (S). Push-out testing, histology, and backscatter scanning electron microscope (SEM) imaging were employed to assess the healing response at 4, 8, and 12 weeks. Push-out testing revealed PC and PCHA surfaces resulted in significantly greater mechanical fixation over all other implant types at all time points (p <.05). HA coating on the grit-blasted surface significantly improved fixation at 8 and 12 weeks (p <.05). The addition of HA onto the porous coating did not significantly improve fixation in this model. Quantification of ingrowth/ongrowth from SEM images revealed that HA coating of the grit-blasted surfaces resulted in significantly more ongrowth at 4 weeks (p <.05).
We investigated factors that were thought to be associated with an increased incidence of squeaking of ceramic-on-ceramic total hip replacements. Between June 1997 and December 2008 the three senior authors implanted 2406 primary total hip replacements with a ceramic-on-ceramic bearing surface. The mean follow-up was 10.6 years. The diagnosis was primary osteoarthritis in each case, and no patient had undergone previous surgery to the hip. We identified 74 squeaking hips (73 patients) giving an incidence of 3.1% at a mean follow-up of 9.5 years (4.1 to 13.3). Taller, heavier and younger patients were significantly more likely to have hips that squeaked. Squeaking hips had a significantly higher range of post-operative internal (p = 0.001) and external rotation (p = 0.003) compared with silent hips. Patients with squeaking hips had significantly higher activity levels (p = 0.009). A squeaking hip was not associated with a significant difference in patient satisfaction (p = 0.24) or Harris hip score (p = 0.34). Four implant position factors enabled good prediction of squeaking. These were high acetabular component inclination, high femoral offset, lateralisation of the hip centre and either high or low acetabular component anteversion. This is the largest study to date to examine patient factors and implant position factors that predispose to squeaking of a ceramic-on-ceramic hip. The results suggest that factors which increase the mechanical forces across the hip joint and factors which increase the risk of neck-to-rim impingement, and therefore edge-loading, are those that predispose to squeaking.
Cementless primary total hip prostheses with a third-generation alumina-on-alumina bearing showed very low wear and were associated with minimal osteolysis at the time of follow-up, at a minimum of five years.
The aim of this study was to evaluate the outcome of joint arthroplasty in obese and non-obese patients. We reviewed 2,026 consecutive primary total hip and 535 primary total knee arthroplasties performed for osteoarthritis. Patients were separated into two groups according to their body mass index (BMI): non-obese (BMI < 30) and obese (BMI ≥ 30). Their survivorships were compared. Case controlled studies were performed with 134 hip and 50 knee arthroplasties in obese patients. Each was matched individually with a control and their outcome compared. Log rank tests for equality of survival showed no difference in the survival for hip and knee arthroplasty at 11 and ten years, respectively. The obese group had significantly lower postoperative hip and knee scores at latest follow-up, especially in the range of motion. Overall patient satisfaction scores were comparable. There were no significant differences in the radiographic analysis of both hip and knee implants. Revision was used as an end point for the survival analysis. Functional scores (Harris hip score and Hospital for Special Surgery knee score), satisfaction for surgery and radiographic features were used as outcome measures for comparison. The mid-term survival of total hip and knee arthroplasty is not adversely affected by obesity. Despite lower clinical scores, the obese patients were satisfied with the results of their surgery and have an equivalent mid-term survival rate. It would be unreasonable to deny patients arthroplasty surgery purely on the basis of a BMI indicating obesity.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.