Failure to establish an appropriate balance between pro- and anti-inflammatory immune responses is believed to contribute to pathogenesis of severe malaria. To determine whether this balance is maintained by classical regulatory T cells (CD4+ FOXP3+ CD127−/low; Tregs) we compared cellular responses between Gambian children (n = 124) with severe Plasmodium falciparum malaria or uncomplicated malaria infections. Although no significant differences in Treg numbers or function were observed between the groups, Treg activity during acute disease was inversely correlated with malaria-specific memory responses detectable 28 days later. Thus, while Tregs may not regulate acute malarial inflammation, they may limit memory responses to levels that subsequently facilitate parasite clearance without causing immunopathology. Importantly, we identified a population of FOXP3−, CD45RO+ CD4+ T cells which coproduce IL-10 and IFN-γ. These cells are more prevalent in children with uncomplicated malaria than in those with severe disease, suggesting that they may be the regulators of acute malarial inflammation.
Heme oxygenase 1 (HO-1) is an essential enzyme induced by heme and multiple stimuli associated with critical illness. In humans, polymorphisms in the HMOX1 gene promoter may influence the magnitude of HO-1 expression. In many diseases including murine malaria, HO-1 induction produces protective anti-inflammatory effects, but observations from patients suggest these may be limited to a narrow range of HO-1 induction, prompting us to investigate the role of HO-1 in malaria infection. In 307 Gambian children with either severe or uncomplicated P. falciparum malaria, we characterized the associations of HMOX1 promoter polymorphisms, HMOX1 mRNA inducibility, HO-1 protein levels in leucocytes (flow cytometry), and plasma (ELISA) with disease severity. The (GT) n repeat polymorphism in the HMOX1 promoter was associated with HMOX1 mRNA expression in white blood cells in vitro , and with severe disease and death, while high HO-1 levels were associated with severe disease. Neutrophils were the main HO-1-expressing cells in peripheral blood, and HMOX1 mRNA expression was upregulated by heme-moieties of lysed erythrocytes. We provide mechanistic evidence that induction of HMOX1 expression in neutrophils potentiates the respiratory burst, and propose this may be part of the causal pathway explaining the association between short (GT) n repeats and increased disease severity in malaria and other critical illnesses. Our findings suggest a genetic predisposition to higher levels of HO-1 is associated with severe illness, and enhances the neutrophil burst leading to oxidative damage of endothelial cells. These add important information to the discussion about possible therapeutic manipulation of HO-1 in critically ill patients.
Erythrocyte invasion is central to malaria parasite replication and virulence. Plasmodium falciparum parasites use different alternative erythrocyte receptors and vary in expression of erythrocyte-binding antigenic (EBA) proteins and reticulocyte-binding protein homologues (Rh). Parasite invasion phenotypes and schizont-stage transcript expression profiles of the 8 eba and Rh protein-coding genes without internal stop codons were determined for 163 clinical isolates cultured ex vivo in The Gambia. There was extensive diversity in ability to invade erythrocytes treated with neuraminidase, trypsin, or chymotrypsin, and severe malaria isolates were less restricted by trypsin treatment than were mild malaria isolates (P = .015). Expression profiles of the eba and Rh genes showed distinct clusters indicating coordinated alternative transcription. The most divergent of 5 major clusters was dominated by Rh2b, with virtually no expression of eba175 or eba140 genes (which were dominant in the other 4 clusters). Particular transcripts were significantly correlated with parasitemia (Rh5 was positively correlated and eba140 negatively correlated; P < .01 for both) and age of patients (eba181 was positively correlated and eba175 negatively correlated; P < .001 for both) but not with invasion phenotypes or severity of malaria. Severe and mild malaria isolates were also evenly represented across the different expression clusters.
Objective To compare oxygen supply options for health facilities in the Gambia and develop a decision-making algorithm for choosing oxygen delivery systems in Africa and the rest of the developing world. Methods Oxygen cylinders and concentrators were compared in terms of functionality and cost. Interviews with key informants using locally developed and adapted WHO instruments, operational assessments, cost-modelling and cost measurements were undertaken to determine whether oxygen cylinders or concentrators were the better choice. An algorithm and a software tool to guide the choice of oxygen delivery system were constructed. Findings In the Gambia, oxygen concentrators have significant advantages compared to cylinders where power is reliable; in other settings, cylinders are preferable as long as transporting them is feasible. Cylinder costs are greatly influenced by leakage, which is common, whereas concentrator costs are affected by the cost of power far more than by capital costs. Only two of 12 facilities in the Gambia were found suitable for concentrators; at the remaining 10 facilities, cylinders were the better option. Conclusion Neither concentrators nor cylinders are well suited to every situation, but a simple options assessment can determine which is better in each setting. Nationally this would result in improved supply and lower costs by comparison with conventional cylinders alone, although ensuring a reliable supply would remain a challenge. The decision algorithm and software tool designed for the Gambia could be applied in other developing countries.Une traduction en français de ce résumé figure à la fin de l'article. Al final del artículo se facilita una traducción al español. املقالة. لهذه الكامل النص نهاية يف الخالصة لهذه العربية الرتجمة
We searched PubMed Central for all studies or reports of lipoarabinomannan for the diagnosis of pulmonary tuberculosis in children. We used search terms "pulmonary tuberculosis" OR "ptb" AND "child" OR "infant" OR "adolescent" AND "lipoarabinomannan" OR "lam" AND "urine", up to Mar 9, 2020. No language restrictions were applied. Our search returned five relevant publications that included children below 15 years undergoing LAM testing of urine for diagnosis of pulmonary tuberculous using AlereLAM. None of the studies used FujiLAM. The sensitivity of LAM, compared with confirmed TB, ranged from 48•3% to 73•2% for all children. Even though the WHO has recommended the use of AlereLAM to aid in the diagnosis of TB in children and adolescents with HIV, the test still shows sub-optimal sensitivity in most studies.When we searched using the search terms "fuji silvamp tb" OR "fujilam" OR "fuji silvamp tb lam", we found two relevant studies, both of which were performed in adults with HIV and found that FujiLAM had a notably higher sensitivity than AlereLAM. No comparison of the two tests in children has been done to date, and the role of FujiLAM in childhood PTB diagnosis remains unknown.
SUMMARYSETTING: A 42-bed hospital operated by the Medical Research Council (MRC) Unit in The Gambia.OBJECTIVE: To devise, test and evaluate a cost-efficient uninterrupted oxygen system in the MRC Hospital.DESIGN: Oxygen cylinders were replaced with oxygen concentrators as the primary source of oxygen. An uninterruptable power supply (UPS) ensured continuity of power. Hospital staff were trained on the use of the new system. Eight years post-installation, an analysis of concentrator maintenance needs and costs was conducted and user feedback obtained to assess the success of the system.RESULTS: The new system saved at least 51% of oxygen supply costs compared to cylinders, with savings likely to have been far greater due to cylinder leakages. Users indicated that the system is easier to use and more reliable, although technical support and staff training are still needed.CONCLUSION: Oxygen concentrators offer long-term cost savings and an improved user experience compared to cylinders; however, some technical support and maintenance are needed to upkeep the system. A UPS dedicated to oxygen concentrators is an appropriate solution for settings where power interruptions are frequent but short in duration. This approach can be a model for health systems in settings with similar infrastructure.
In North-central Nigeria where HIV is prevalent, ART started before pregnancy is enormously effective in preventing mother-to-child transmission. Adoption of WHO 'Option B+' deserves serious consideration in such settings.
Introduction Adverse drug reactions associated with efavirenz (EFV) therapy are poorly described beyond the first year of treatment. We aimed to describe the incidence and predictors of EFV-related adverse drug reactions (
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.