ObjectivesWe aimed to compare the performance of the C-MAC video laryngoscope (C-MAC) to the Macintosh laryngoscope for intubation of blunt trauma patients in the ED.Material and methodsThis was a prospective randomized study. The primary outcome measure is overall successful intubation. Secondary outcome measures are first attempt successful intubation, Cormack–Lehane (CL) grade, and indicators of the reasons for unsuccessful intubation at the first attempt with each device. Adult patients who suffered from blunt trauma and required intubation were randomized to video laryngoscopy with C-MAC device or direct laryngoscopy (DL).ResultsDuring a 17-month period, a total of 150 trauma intubations were performed using a C-MAC and DL. Baseline characteristics of patients were similar between the C-MAC and DL group. Overall success for the C-MAC was 69/75 (92%, 95% CI 0.83 to 0.96) while for the DL it was 72/75 (96%, 95% CI 0.88 to 0.98). First attempt success for the C-MAC was 47/75 (62.7%, 95% CI 0.51 to 0.72) while for the DL it was 44/75 patients (58.7%, 95% CI 0.47 to 0.69). The mean time to achieve successful intubation was 33.4 ± 2.5 s for the C-MAC versus 42.4 ± 5.1 s for the DL (p = 0.93). There was a statistically significant difference between the DL and C-MAC in terms of visualizing the glottic opening and esophageal intubation in favor of the C-MAC (p = 0.002 and p = 0.013 respectively).Discussion and conclusionThe overall success rates were similar. The C-MAC demonstrated improved glottic view and decrease in esophageal intubation rate.
Objective
Recently, a cardiac sonography finding, early systolic notching (ESN), was reported with high sensitivity and specificity for the diagnosis of pulmonary embolism (PE) in a limited population. The aim of this study was to determine the diagnostic accuracy of ESN finding for PE in emergency department (ED) patients.
Method
This prospective multicenter study was conducted in 4 academic EDs. All patients who underwent computed tomography angiography for suspected PE were included in the study. After inclusion, cardiac ultrasound including the right ventricular outflow tract Doppler signal was performed. The diagnostic tests of ESN finding were used for PE and its subgroups.
Results
In the study, 183 of 201 patients met the study criteria. Of all patients, 52.5% had PE (n = 96), and 19.7% (n = 36) had ESN finding. In all ED patients, the sensitivity of ESN for PE was 34% (95% CI 25–45), and the specificity was 97% (95% CI 90–99). In the subgroup analysis, the sensitivity of ESN for PE with high or intermediate‐high risk was 69% (95% CI 49–85), and the specificity was 90% (95% CI 84–94). Inter‐rater reliability for ESN finding between the cardiologist and emergency physician was strong with a kappa statistic of 0.87.
Conclusion
The pulmonary Doppler flow of ESN was moderate to high specific but low sensitive for PE in all ED patients. In the subgroup analysis, this finding was moderate specific and low sensitive.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.