Despite the success of treating rheumatic disorders with biologic therapies, joint replacement surgery still remains the final treatment option in many cases. Approximately 1.5 million joint arthroplastic operations are performed annually worldwide. Implant failure due to massive bone loss and aseptic loosening of prostheses, however, is a major complication of joint replacement, which can lead to high socioeconomic burdens both for the individual patient and for health-care systems. To date, there is no approved drug therapy to prevent or inhibit periprosthetic osteolysis, and aseptic loosening of prostheses can only be overcome by surgical revision. Research during the past decade, however, has unravelled much of the pathogenesis of aseptic prosthesis loosening and preclinical studies have identified potential targets for pharmaceutical treatments. This article highlights the importance of a cooperative interaction between rheumatologists and orthopedic surgeons, and presents novel insights into the molecular mechanisms behind aseptic loosening of prostheses. In addition, we outline potential perspectives for the development of future therapeutic strategies for this devastating complication.
Background Accurate alignment of the components in total knee arthroplasty is important. By use of postoperative CT controls, we studied the ability of a robotic effector to accurately place and align total knee arthroplasty (TKA) components according to a purely CT-based preoperative plan.Patients and methods Robotic TKA was performed in 13 patients (6 men) with primary gonarthrosis. Locator screws were placed into femur and tibia under spinal anesthesia. A CT-scan including the femoral head, knee and ankle was performed. In the preoperative planning software, virtual components were positioned into the CT volume. In a second operation, the robot milled femur and tibia with a high-speed milling tool according to the preoperative plan. On the 10th day, CT controls were performed following the same protocol as preoperatively.Results The mean deviation of the postoperative from the preoperatively planned mechanical axis was 0.2° (95% CI: -0.1° to 0.5°). The accuracy of angular component placement in frontal, sagittal and transverse planes was within ± 1.2°, and the accuracy of linear component placement in mediolateral, dorsoventral and caudocranial directions was within ± 1.1 mm.Interpretation Robotic TKA allows placement of components with unparalleled accuracy, but further development is mandatory to integrate soft-tissue balancing into the procedure and make it faster, easier and cheaper.
iCT-N using automated referencing allows for safe, highly accurate multilevel instrumentation of the entire thoracolumbosacral spine and ilium, rendering additional intraoperative imaging dispensable. In addition, automated registration is time-efficient and significantly reduces the need for re-registration in multilevel surgery.
The present investigation aims to evaluate periprosthetic bone remodelling after total knee arthroplasty by the use of dual-energy X-ray absorptiometry (DXA). Twelve patients affected by osteoarthrosis of the knee joint underwent primary total knee arthroplasty at an average age of 70.5 years. None of them had received a knee prosthesis before on the contralateral side. Anteroposterior and lateral DXA measurements of the femur, tibia and total knee (both sides) were taken 2 weeks, 3 and 9 months postoperatively. The 2-week measurement was used as an individual reference value to be compared with the 3- and 9-month findings. In addition, the contralateral knee was investigated also in order to estimate how far bone mineral loss was due to implantation or to an individual decline in bone mineral density (BMD). The comparison of BMD values after knee arthroplasty revealed a conspicuous decrease of bone density within 9 months. Bone mineral loss amounted to an average of 9.2% in anteroposterior and 17.8% in lateral DXA measurements. Lateral femur shots showed an average decrease of density of even 21.5%. In contrast, the BMD values of the contralateral knees remained almost unchanged. DXA, especially lateral shots of the femur, promises to be a suitable method for early assessment of periprosthetic bone remodelling after total knee arthroplasty.
The purpose of this study was to analyse the number and types of secondary fractures, and to investigate the impact of intradiscal cement leaks for adjacent vertebral fractures. Patients with osteoporotic vertebral fractures were treated with vertebroplasty. Results were documented and prospectively followed by means of computed tomography (CT) and magnetic resonance imaging. The frequency and the types of cement leakages were analysed from multiplanar CT images and secondary fractures were characterised as follows: (1) adjacent fracture in the immediate vicinity of an augmented vertebra; (2) sandwich fracture, fracture of an untreated vertebra between two vertebrae that had been previously augmented, and (3) distant fractures not in the vicinity of augmented vertebrae. A total of 385 osteoporotic vertebral fractures were treated in 191 patients (61 men, 130 women, age 70.7 +/- 9.7 years). The overall rate of cement leaks was 55.6%, including all leaks detectable by CT. Intradiscal leaks through the upper, the lower, and both endplates occurred in 18.2%, 6.8%, and 2.6%, respectively. In 39 patients (20.4%), a total of 72 secondary fractures occurred: 30 adjacent fractures in 23 patients (12.0%) with a time to fracture of 2 months [median; 1.0/4.0 months, first/third quartile (Q1/Q3)]; 11 secondary sandwich fractures in 11 patients (5.8%) after 1.5 months (median; 0.25/7.5 months, Q1/Q3); and 31 distant fractures in 20 patients (10.5%) after 5 months (median; 2.0/8.0 months, Q1/Q3). Ten of 30 adjacent fractures occurred in the presence of pre-existing intradiscal cement leaks and 20 where there was no leakage. Six of 11 sandwich fractures occurred in the presence of intradiscal leaks (five leaks in both adjacent disc spaces, one leak in the lower disc space) and five where there was no leakage. The rate of secondary adjacent and non-adjacent fractures is quite similar and there is no specific impact of intradiscal leakages on the occurrence of adjacent secondary fractures. Adjacent fractures occur sooner than distant secondary fractures. Sandwich fractures are associated with specific biomechanical conditions, with a 37.9% fracture rate in sandwich constellations.
Image-guided spinal instrumentation using iCT-N with automated referencing allows safe, highly accurate multilevel instrumentation of the cervical and upper and midthoracic spine. In addition, iCT-N significantly reduces the need for reregistration in multilevel surgery.
Instrumented correction of adult deformity was significantly facilitated by iCT navigation, eliminating radiation exposure to the surgeon. Intraoperative biplanar CT scout views including pelvis and shoulders allow comprehensive assessment of multiplanar deformity correction. Fusion rates obtained with less invasive access equal those of conventional open technique.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.