In this paper, a modified expanded graphite composite electrode based on natural zeolitic volcanic tuff modified with silver (EG-Ag-Z-Epoxy) was developed. Cyclic voltammetry measurements revealed a reasonably fast electron transfer and a good stability of the electrode in 0.1 M NaOH supporting electrolyte. This modified electrode exhibited moderate electrocatalytic effect towards urea oxidation, allowing its determination in aqueous solution. The linear dependence of the current versus urea concentration was reached using square-wave voltammetry in the concentrations range of urea between 0.2 to 1.4 mM, with a relatively low limit of detection of 0.05 mM. A moderate enhancement of electroanalytical sensitivity for the determination of urea at EG-Ag-Z-Epoxy electrode was reached by applying a chemical preconcentration step prior to voltammetric/amperometric quantification.
The aim of this study is to prepare and characterize two types of silver-functionalized carbon nanofiber (CNF) composite electrodes, i.e., silver-decorated CNF-epoxy and silver-modified natural zeolite-CNF-epoxy composite electrodes suitable for ibuprofen detection in aqueous solution. Ag carbon nanotube composite electrode exhibited the best electroanalytical parameters through applying preconcentration/differential-pulsed voltammetry scheme.
An exfoliated graphite-polystyrene composite electrode was evaluated as an alternative electrode in the oxidation and the determination of oxalic acid in 0.1 M Na 2 SO 4 supporting electrolyte. Using CV, LSV, CA procedures, linear dependences I vs. C were obtained in the concentrations range of oxalic acid between 0.5 to 3 mM, with LOD =0.05 mM, and recovery degree of 98%, without need of surface renewing between successive runs. The accuracy of the methods was evaluated as excellent comparing the detection results with that obtained using conventional KMnO 4 titration method. In addition, the apparent diffusion coefficient of oxalic acid D was found to be around 2.89 · 10 -8 cm 2 ·s -1 by CA and CV.
In this study, the detection protocols for the individual, selective, and simultaneous determination of ibuprofen (IBP) and diclofenac (DCF) in aqueous solutions have been developed using HKUST-1 metal-organic framework-carbon nanofiber composite (HKUST-CNF) electrode. The morphological and electrical characterization of modified composite electrode prepared by film casting was studied by scanning electronic microscopy and four-point-probe methods. The electrochemical characterization of the electrode by cyclic voltammetry (CV) was considered the reference basis for the optimization of the operating conditions for chronoamperometry (CA) and multiple-pulsed amperometry (MPA). This electrode exhibited the possibility to selectively detect IBP and DCF by simple switching the detection potential using CA. However, the MPA operated under optimum working conditions of four potential levels selected based on CV shape in relation to the potential value, pulse time, and potential level number, and order allowed the selective/simultaneous detection of IBP and DCF characterized by the enhanced detection performance. For this application, the HKUST-CNF electrode exhibited a good stability and reproducibility of the results was achieved.
The aim of this study was the preparation, characterization, and application of a multi-wall carbon nanotubes-epoxy composite electrode (MWCNT-EP) with 25%, wt. MWCNTs loading for the voltammetric/amperometric determination of pentachlorophenol (PCP) in aqueous solutions. The structural and morphological aspects of the MWCNT-EP composite electrode were examined by scanning electron microscopy. The electrical properties were characterized by direct-current conductivity measurements in relation with the percolation threshold. The electrochemical behavior of PCP at the MWCNT-EP composite electrode was investigated using cyclic voltammetry in 0.1 M Na2SO4 supporting electrolyte in order to establish the parameters for amperometric/voltammetric determination of PCP. The linear dependence of current vs. PCP concentrations was reached in a wide concentration range from 0.2 to 12 μM PCP using cyclic voltammetry, differential-pulsed voltammetry, square-wave voltammetry, chronoamperometry, and multiple-pulsed amperometry techniques. The best electroanalytical performances of this composite electrode were achieved using a pre-concentration/square-wave voltammetric technique and also multiple-pulsed amperometry techniques envisaging the practical applications. The ease of preparation, high sensitivity, and stability of this composite electrode should open novel avenues and applications for fabricating robust sensors for detection of many important species.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.