Femtosecond laser cataract surgery had a learning curve during the first 100 cases. With cautious surgical technique, the complications can be avoided. The femtosecond laser-assisted method was efficient and safe for cataract surgery.
The results indicate that femtosecond laser can be successfully used in certain cases of phacomorphic glaucoma, even if mechanical pupil dilatation is needed.
PurposeTo assess the correlation between keratoconus severity and intereye asymmetry of pachymetric data and posterior elevation values and to evaluate their combined accuracy in discriminating normal corneas from those with keratoconus.MethodsThis study included 97 patients: 65 subjects with bilateral normal corneas (NC) and 32 with keratoconus (KC). Central corneal thickness (CCT), thinnest corneal thickness (ThCT) and posterior elevation (PE) at the thinnest point of the cornea were measured in both eyes using Scheimpflug imaging. Intereye asymmetry and its correlation with keratoconus severity were calculated for each variable. The area under the receiver operating characteristic curve (AUROC) was used to compare predictive accuracy of different variables for keratoconus.ResultsIn normal eyes, intereye differences were significantly lower compared with the keratoconus eyes (p<0.001, for CCT, ThCT and PE). There was a significant exponential correlation between disease severity and intereye asymmetry of steep keratometry (r2 = 0.55, p<0.001), CCT (r2 = 0.39, p<0.001), ThCT (r2 = 0.48, p<0.001) and PE (r2 = 0.64, p<0.001). After adjustment for keratoconus severity, asymmetry in thinnest pachymetry proved to be the best parameter to characterize intereye corneal asymmetry in keratoconus. This variable had high accuracy and significantly better discriminating ability (AUROC: 0.99) for KC than posterior elevation (AUROC: 0.96), ThCT (AUROC: 0.94) or CCT (AUROC: 0.92) alone.ConclusionsThere is an increased intereye asymmetry in keratometry, pachymetry and posterior corneal elevation values in keratoconic patients compared to subjects with normal corneas. Keratoconus patients with more severe disease are also more asymmetric in their disease status which should be taken into account during clinical care.
According to the current results in a porcine eye model, FLC had less average resistance to capsule tear than CCC, but the weakest openings were seen in the CCC group.
Anterior capsule openings created at a high energy level were slightly weaker and less extensible than those created at low or intermediate levels, possibly due to the increased thermal effect of photo-disruption.
Aberrations of the posterior corneal surface seem to compensate for wavefront alterations of the anterior cornea, decreasing the amount of wavefront error regarding the total cornea in myopic patients. PRK induced increased HOAs with respect to the anterior corneal surface; however, the posterior surface remained stable. The increase in the HOAs was measured to be significantly larger above 76.78 μm photoablation depth.
Topographic indices indicate corneal flattening after CXL in the long term. Monitoring keratoconus index and index of height asymmetry should be the preferred choice in daily clinical practice because changes in values of these indices are independent from initial corneal thickness.
Application of this multifunctional femtosecond laser performing LASIK proved to be a safe and effective method regarding predictability of flap thickness.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.