PurposeTo assess the correlation between keratoconus severity and intereye asymmetry of pachymetric data and posterior elevation values and to evaluate their combined accuracy in discriminating normal corneas from those with keratoconus.MethodsThis study included 97 patients: 65 subjects with bilateral normal corneas (NC) and 32 with keratoconus (KC). Central corneal thickness (CCT), thinnest corneal thickness (ThCT) and posterior elevation (PE) at the thinnest point of the cornea were measured in both eyes using Scheimpflug imaging. Intereye asymmetry and its correlation with keratoconus severity were calculated for each variable. The area under the receiver operating characteristic curve (AUROC) was used to compare predictive accuracy of different variables for keratoconus.ResultsIn normal eyes, intereye differences were significantly lower compared with the keratoconus eyes (p<0.001, for CCT, ThCT and PE). There was a significant exponential correlation between disease severity and intereye asymmetry of steep keratometry (r2 = 0.55, p<0.001), CCT (r2 = 0.39, p<0.001), ThCT (r2 = 0.48, p<0.001) and PE (r2 = 0.64, p<0.001). After adjustment for keratoconus severity, asymmetry in thinnest pachymetry proved to be the best parameter to characterize intereye corneal asymmetry in keratoconus. This variable had high accuracy and significantly better discriminating ability (AUROC: 0.99) for KC than posterior elevation (AUROC: 0.96), ThCT (AUROC: 0.94) or CCT (AUROC: 0.92) alone.ConclusionsThere is an increased intereye asymmetry in keratometry, pachymetry and posterior corneal elevation values in keratoconic patients compared to subjects with normal corneas. Keratoconus patients with more severe disease are also more asymmetric in their disease status which should be taken into account during clinical care.
PurposeTo investigate corneal sensitivity to selective mechanical, chemical, and thermal stimulation and to evaluate their relation to dry eye symptoms in patients with keratoconus.MethodsCorneal sensitivity to mechanical, chemical, and thermal thresholds were determined using a gas esthesiometer in 19 patients with keratoconus (KC group) and in 20 age-matched healthy subjects (control group). Tear film dynamics was assessed by Schirmer I test and by the non-invasive tear film breakup time (NI-BUT). All eyes were examined with a rotating Scheimpflug camera to assess keratoconus severity.ResultsKC patients had significatly decreased tear secretion and significantly higher ocular surface disease index (OSDI) scores compared to controls (5.3±2.2 vs. 13.2±2.0 mm and 26.8±15.8 vs. 8.1±2.3; p<0.001). There was no significant difference in NI-BUT between the two groups (KC: 9.8±4.8 vs. control: 10.7±3.8; p>0.05). The mean threshold for selective mechanical (KC: 139.2±25.8 vs. control: 109.1±24.0 ml/min), chemical (KC: 39.4±3.9 vs. control: 35.2±1.9%CO2), heat (KC: 0.91±0.32 vs. control: 0.54±0.26 Δ°C) and cold (KC: 1.28±0.27 vs. control: 0.98±0.25 Δ°C) stimulation in the KC patients were significantly higher than in the control subjects (p<0.001, for all parameters). No correlation was found between age and mechanical, chemical, heat or cold thresholds in the patients with KC (p>0.05), whereas in the control subjects both mechanical (r = 0.52, p = 0.02), chemical (r = 0.47, p = 0.04), heat (r = 0.26, p = 0.04) and cold threshold (r = 0.40, p = 0.03) increased with age. In the KC group, neither corneal thickness nor tear flow, NI-BUT or OSDI correlated significantly with mechanical, chemical, heat or cold thresholds (p>0.05 for all variables).ConclusionsCorneal sensitivity to different types of stimuli is decreased in patients with keratoconus independently of age and disease severity. The reduction of the sensory input from corneal nerves may contribute to the onset of unpleasant sensations in these patients and might lead to the impaired tear film dynamics.
Prolonged use of 0.15% zinc-hyaluronate results in an improvement of tear film stability and a decrease of dry eye complaints. The decrease in corneal mechano-and polymodal receptor excitability suggests that zinc-hyaluronate helps to recover normal corneal sensitivity, and thus might have a beneficial additional effect on reducing ocular surface complaints in dry eye patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.