2014
DOI: 10.3928/1081597x-20140827-01
|View full text |Cite
|
Sign up to set email alerts
|

Analysis of Planned and Postoperatively Measured Flap Thickness After LASIK Using the LenSx Multifunctional Femtosecond Laser System

Abstract: Application of this multifunctional femtosecond laser performing LASIK proved to be a safe and effective method regarding predictability of flap thickness.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Notably, data from a past study among experienced and novice LASIK surgeons indicated a fellowship-training program based on a standardized surgical protocol to result in statistically comparable outcomes between an expert surgeon and a fellowship-trained surgeon when newly transitioned from mechanical microkeratome to a FS laser flap creation. [20] However, it should be noted that, while FS laser-created LASIK flap has been reported to be a uniform flap that may contribute to more predictable refractive and wavefront outcomes, [5,9,21] the clinical relevance of FS laser is considered to remain controversial. [5,19] In a past study comparing iFS 150-kHz vs. LenSx FS lasers in correction myopia, authors reported association of iFS 150 kHz with significantly lower intra-FT range at…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Notably, data from a past study among experienced and novice LASIK surgeons indicated a fellowship-training program based on a standardized surgical protocol to result in statistically comparable outcomes between an expert surgeon and a fellowship-trained surgeon when newly transitioned from mechanical microkeratome to a FS laser flap creation. [20] However, it should be noted that, while FS laser-created LASIK flap has been reported to be a uniform flap that may contribute to more predictable refractive and wavefront outcomes, [5,9,21] the clinical relevance of FS laser is considered to remain controversial. [5,19] In a past study comparing iFS 150-kHz vs. LenSx FS lasers in correction myopia, authors reported association of iFS 150 kHz with significantly lower intra-FT range at…”
Section: Discussionmentioning
confidence: 99%
“…According to our experience, in the first 20 operations flaps were thinner than planned by −4.6 μm and SD of FT was 10.8 μm (range, −9.3 to +11.3 μm), whereas in the next 50 operations, flaps were thicker than planned by +3.0 μm and SD of FT was 6.6 μm (range, −11.0 to +13.7 μm). Notably, in the first study to evaluate the visual outcomes and FT accuracy of the LASIK performed with new LenSx multifunctional FS laser system (Alcon Laboratories) by Juhasz et al [ 9 ], the authors reported good visual results and a high FT predictability with the LenSx device when they performed a targeted thick corneal flap of 140 μm in all cases. However, they also emphasized that after gaining an initial experience with the device, the FT was set to the current depth of 110 μm for use in our everyday clinical practice [ 9 ].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations