Dr. Alió is a clinical research investigator for Hanita Lenses, Carl Zeiss Meditec AG, Topcon Medical Systems, Inc., Oculentis GmbH, and Akkolens International BV. Dr. Dell is a consultant to Bausch & Lomb and Abbott Medical Optics, Inc. Dr. Slade is a consultant to Alcon Surgical, Inc., Carl Zeiss Meditec AG, and Bausch & Lomb. None of the authors has a financial or proprietary interest in any material or method mentioned.
Femtosecond laser cataract surgery had a learning curve during the first 100 cases. With cautious surgical technique, the complications can be avoided. The femtosecond laser-assisted method was efficient and safe for cataract surgery.
Objectives:
To evaluate the repeatability and reproducibility of the Carl Zeiss Meditec IOLMaster 700, which uses swept-source optical coherence tomography technology, along with its agreement with the IOLMaster 500 and Lenstar LS 900.
Methods:
In a clinical practice, complete measurements were taken on one eye of 100 subjects: 51 with cataracts and 49 with clear lenses. Three sets of measurements were taken by 3 operators with three different IOLMaster 700 units, and one operator took 3 measurements with the IOLMaster 500 and the Lenstar. A random-effects model of analysis of variance was used to estimate the repeatability and reproducibility. The 95% limits of agreement (95% LoA) were calculated for all comparisons.
Results:
Comparing the IOLMaster 700 and IOLMaster 500 in cataract patients, 95% LoA were −0.01 to +0.06 mm for axial length, −0.44 to +0.27 D for corneal power, and −0.18 to +0.17 mm for anterior chamber depth. Comparing the IOLMaster 700 and Lenstar for corneal thickness and lens thickness yielded 95% LoA of −4 to +13 μm and −0.26 to +0.41 mm, respectively. The repeatability and reproducibility limits for the IOLMaster 700 were ±0.014 and ±0.023 mm for axial length; ±0.26 and ±0.27 D for corneal power; ±7 and ±11 μm for corneal thickness; ±0.02 and ±0.02 mm for anterior chamber depth; and ±0.02 and ±0.05 mm for lens thickness, respectively.
Conclusions:
There was good agreement between the IOLMaster 700 and comparator instruments and superior or equivalent precision. Some differences were noted, but not considered clinically meaningful.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.