BackgroundNovel non-invasive brain stimulation techniques such as transcranial direct current stimulation (tDCS) have been developed in recent years. TDCS-induced corticospinal excitability changes depend on two important factors current intensity and stimulation duration. Despite clinical success with existing tDCS parameters, optimal protocols are still not entirely set.Objective/hypothesisThe current study aimed to investigate the effects of four different anodal tDCS (a-tDCS) current densities on corticospinal excitability.MethodsFour current intensities of 0.3, 0.7, 1.4 and 2 mA resulting in current densities (CDs) of 0.013, 0.029, 0.058 and 0.083 mA/cm2 were applied on twelve right-handed (mean age 34.5±10.32 yrs) healthy individuals in different sessions at least 48 hours apart. a-tDCS was applied continuously for 10 minute, with constant active and reference electrode sizes of 24 and 35 cm2 respectively. The corticospinal excitability of the extensor carpi radialis muscle (ECR) was measured before and immediately after the intervention and at 10, 20 and 30 minutes thereafter.ResultsPost hoc comparisons showed significant differences in corticospinal excitability changes for CDs of 0.013 mA/cm2 and 0.029 mA/cm2 (P = 0.003). There were no significant differences between excitability changes for the 0.013 mA/cm2 and 0.058 mA/cm2 (P = 0.080) or 0.013 mA/cm2 and 0.083 mA/cm2 (P = 0.484) conditions.ConclusionThis study found that a-tDCS with a current density of 0.013 mA/cm2 induces significantly larger corticospinal excitability changes than CDs of 0.029 mA/cm2. The implication is that might help to avoid applying unwanted amount of current to the cortical areas.
We aimed to determine, using transcranial magnetic stimulation (TMS), the number of elicited motor evoked potentials (MEPs) that induces the highest intra- and inter-sessions reliability for the extensor carpi radialis (ECR) and first dorsal interosseus (FDI) muscles. Twelve healthy subjects participated in this study on two separate days. Single pulse magnetic stimuli were triggered with Magstim 2002 to obtain MEPs from the muscles of interest, with the subjects in a relaxed position. Reliability of MEP responses was investigated in three blocks of 5, 10 and 15 trials. The intra- and inter-session reliability of the MEPs' amplitudes and latencies were assessed using intraclass correlation coefficients (ICCs). Repeated measures ANOVA and paired t-tests revealed no significant time effect in the MEP amplitude and latency measurements (P>0.05). The ICCs indicated high intra-session reliability in the MEPs' amplitudes for the ECR and FDI muscles (0.77 to 0.99, 0.90 to 0.99, respectively) and latency (0.80 to 1.00, 0.75 to 0.97, respectively). The MEPs' amplitudes also had high inter-session reliability (0.84 to 0.97, 0.88 to 0.93, respectively), as did their latency (0.80 to 0.90, 0.75 to 0.97, respectively). Highest intra- and inter-session reliability was achieved for blocks of 10 and 15 trials. Our data suggest that intra- and inter-session comparisons should be performed using at least 10 MEPs in “combined hotspot” stimulation technique to ensure highest reliability.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.