We report two cases of ocular prosthesis fabrication that make use of a transparent graph grid for positioning the iris disk. The custom-made ocular prostheses achieved intimate contact with the tissue bed enabling ideal fit. As asymmetry may result in a squint-eyed appearance, proper positioning of the iris disk in the scleral wax pattern is vital to fabricating the custom-made artificial eye. The position of the iris disk in the custom-made ocular prosthesis was in symmetry with that of the natural eye, restoring esthetics of the patient.
Background The purpose of this study evaluates and compares the effect of surface roughness (Ra) and color stability on computer-aided design/computer-aided manufacturing (CAD/CAM) hybrid resin (Vita Enamic), feldspathic (Vitablocs® Mark II), and lithium disilicate Zirconia (Vita Suprinity) glazed or polished ceramics immersed in hot Arabic Qahwa and cold coffee. Methods A total of 96 standardized samples were prepared from CAD/CAM restorative materials. Half of the samples were polished as per the manufacturer’s instructions using a porcelain polishing kit, and the other half were glazed. Samples were distributed and immersed in hot Arabian Qahwa and cold coffee followed by thermocycling. Ra measurements and color changes were conducted before and after immersion. SEM images were captured from each type of glazed or polished ceramic. One-way ANOVA paired Student’s t-test, and Bonferroni test were conducted to detect significant difference between the groups. P > 0.05 was a significant level. Results Of all the tested samples, Ra increased without any significant difference; however, mean color changes (ΔE*) showed significant differences. An increase in Ra was noted for all the glazed and polished samples after immersion and thermocycling. However, differences were significant only in VM II. In addition, ΔE* was significant only in Vita Suprinity (VS) samples. For immersion groups, significant Ra changes were noticed in glazed samples, only in Vita Enamic (VE) with no ΔE*. In polished samples, mean Ra changes were observed in VM II and VS samples. Significant differences were also noticed in polished VE and VS subgroups of ΔE*. Conclusions Ra affects all the tested samples, providing higher values on the polished specimens. The ΔE* caused by hot Arabic Qahwa and cold coffee on glazed or polished CAD/CAM restorative materials were clinically acceptable.
Cataract is the second leading cause of preventable blindness on the globe. Several programs across the country have been running efficiently to increase the cataract surgical rates and decrease blindness due to cataract. The current COVID-19 pandemic has led to a complete halt of these programs and thus accumulating all the elective cataract procedures. At present with the better understanding of the safety precautions among the health care workers and general population the Government of India (GoI) has given clearance for functioning of eye care facilities. In order to facilitate smooth functioning of every clinic, in this paper, we prepared preferred practice pattern based on consensus discussions between leading ophthalmologists in India including representatives from major governmental and private institutions as well as the All India Ophthalmological Society leadership. These guidelines will be applicable to all practice settings including tertiary institutions, corporate and group practices and individual eye clinics. The guidelines include triage, use of personal protective equipment, precautions to be taken in the OPD and operating room as well for elective cataract screening and surgery. These guidelines have been prepared based on current situation but are expected to evolve over a period of time based on the ongoing pandemic and guidelines from GoI.
CAD/CAM technology is gaining popularity and replacing archaic conventional procedures for fabricating dentures. CAD/CAM supports using a digital workflow reduce the number of visits, chair time, and laboratory time, making it attractive to patients. This study aimed to provide a comparative review of complete dentures manufactured using CAD/CAM and conventional methods. The PubMed/Medline, Science Direct, Cochrane, and Google Scholar databases were searched for studies published in English within the last 11 years (from 2011 to 2021). The keywords used were “computer-engineered complete dentures”, “CAD/CAM complete dentures”, “computer-aided engineering complete dentures”, and “digital complete dentures”. The search yielded 102 articles. Eighteen relevant articles were included in this review. Overall, computer-engineered complete dentures have several advantages over conventional dentures. Patients reported greater satisfaction with computer-engineered complete dentures (CECDs) due to better fit, reduced chair time, shorter appointments, and fewer post-insertion visits. CAD/CAM allows for precision and reproducibility with fewer procedures compared to conventional dentures. Polymethyl methacrylate is used as the denture base material for conventional dentures. For CECDs, the resin can be modified and cross-linked to improve its mechanical properties. The advantages of CECDs include a reduced number of appointments, saving chairside time, a digital workflow allowing easy reproducibility and greater patient satisfaction with a better fit.
PURPOSETo compare the changes in the occlusal vertical dimension, activity of masseter muscles and biting force after insertion of immediate denture constructed with conventional, tooth-supported and Implant-supported immediate mandibular complete denture.MATERIALS AND METHODSPatients were selected and treatment was carried out with all the three different concepts i.e, immediate denture constructed with conventional (Group A), tooth-supported (Group B) and Implant-supported (Group C) immediate mandibular complete dentures. Parameters of evaluation and comparison were occlusal vertical dimension measured by radiograph (at three different time intervals), Masseter muscle electromyographic (EMG) measurement by EMG analysis (at three different positions of jaws) and bite force measured by force transducer (at two different time intervals). The obtained data were statistically analyzed by using ANOVA-F test at 5% level of significance. If the F test was significant, Least Significant Difference test was performed to test further significant differences between variables.RESULTSComparison between mean differences in occlusal vertical dimension for tested groups showed that it was only statistically significant at 1 year after immediate dentures insertion. Comparison between mean differences in wavelet packet coefficients of the electromyographic signals of masseter muscles for tested groups was not significant at rest position, but significant at initial contact position and maximum voluntary clench position. Comparison between mean differences in maximum biting force for tested groups was not statistically significant at 5% level of significance.CONCLUSIONImmediate complete overdentures whether tooth or implant supported prosthesis is recommended than totally mucosal supported prosthesis.
Background: The habit of khat (Catha Edulis Forskal) chewing is widely practiced in the southern regions of Saudi Arabia, Yemen, and East Africa. This social habit has tremendous effects on oral and general health of khat chewers. Khat may affect bacterial species in plaque biofilms on oral rehabilitation materials. This preliminary case-controlled study aimed to assess and compare the effect of khat chewing on bacterial biodiversity between nonkhat chewers (NKC) and khat chewers (KC) in oral biofilms on oral rehabilitation materials using polymerase chain reaction (PCR). Material/Methods: Fifty participants were organized into 2 equal groups of NKC and KC, each containing 5 subgroups related to filling material type. Some participants had amalgam (A) or composite (C) restorations, while others had feldspathic porcelain (FP), nickel chromium (NC), and zirconia ceramic (ZC) crowns or bridges. Oral biofilm samples were collected from all participants, DNA was extracted, and samples were subjected to PCR. Bacterial species were then identified and counted. PCR products were sequenced to detect similarity. Partial 16S rRNA gene sequences of the current study samples were compared with 16S rRNA gene sequences from GenBank using BLAST on the National Center for Biotechnology Information website. Results: The Streptococcus sp. was the most common bacterial species among our participants (40; 80%), followed by Lactobacillus and Veillonella spp., accounting for 12% (6) and 8% (4), respectively. Streptococcus sp. was observed equally among NKC and KC, but Lactobacillus and Veillonella spp. were higher in KC and NKC, respectively. Lactobacillus was associated mainly with prosthetic materials, and Streptococcus was found among all examined dental restorative materials. Conclusions: This research concluded that khat chewing significantly affects bacterial biodiversity in oral biofilms in the presence of different restorative and prosthetic dental materials.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.