CFR-PEEK plates proved as reliable as metallic plates in the treatment of proximal humeral fractures. The advantages of these new devices include a better visualization of fracture reduction during intraoperative fluoroscopic assessment and easy hardware removal due to the absence of screw-plate cold fusion.
With this study we want to present our experience in the treatment of retracted distal biceps tendon tear with lacertus fibrosus augmentation. Our surgical technique is an effective and cheap option for chronic-retracted distal biceps tendon lesions. Recovery time is quicker, and integration is faster due to the use of an autologous vascularized graft. Preoperative ultrasound scan is mandatory in order to evaluate LF integrity, thickness and size.
Background
The Oxford Elbow Score (OES) is an English-language questionnaire specifically designed to evaluate surgical elbow outcomes. This scoring system has been translated into other languages. Given the lack of an Italian version of the OES, the present study was designed to establish, culturally adapt, and validate the Italian version.
Methods
The OES questionnaire was culturally adapted to Italian patients in accordance with the literature guidelines with a pilot phase including seven patients with elbow problems and seven healthy subjects. The study includes 110 participants from three hospitals, who underwent elbow surgery for acute (70%) or chronic diseases. At least one month after elbow surgery, at the “index visit”, the physician completed the Mayo Elbow Performance Index and patients completed the following questionnaires: the Italian OES, the shortened version of the Disability of Arm, Shoulder and Hand Questionnaire (
Quick
DASH) and the Short-Form 36 Health Survey. Internal consistency was evaluated using Cronbach's alpha. Reproducibility was assessed using the intraclass correlation coefficient in ten patients who completed the OES again two-three days after the index visit. Construct validity was assessed using Spearman correlation coefficients. Responsiveness was evaluated in 68 patients who answered the questionnaires four months after the index visit, using the Wilcoxon signed-rank test, the effect size and the standardized response mean calculation.
Results
Cronbach's alpha was excellent: 0.86 (0.82-0.90) for OES pain, 0.92 (0.90-0.94) for OES function, and 0.90 (0.87-0.93) for OES social/psychological. The intraclass correlation coefficient was 0.94 (0.78-0.98) for OES pain, 0.91 (0.71-0.97) for OES function, 0.95 (0.83-0.98) for OES social-psychological and 0.93 (0.76-0.98) for OES total. The Spearman ρ was >0.7 for OES pain and
Quick
DASH, for OES function and both
Quick
DASH and Mayo Elbow Performance Index, and for OES social-psychological and
Quick
DASH. Regarding responsiveness, the mean of the changes between the two visits ranged from 33.9 for OES pain, to 44 points for OES function and OES social/psychological. The effect size and the standardized response mean were >0.8 for all OES domains.
Conclusion
This study demonstrates that the Italian version of the OES, translated in accordance with the international standardized guidelines, is reliable, valid, and responsive in patients who have undergone elbow surgery.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.