PostprintThis is the accepted version of a paper published in Journal of The Mechanical Behavior of Biomedical Materials. This paper has been peer-reviewed but does not include the final publisher proofcorrections or journal pagination. Citation for the original published paper (version of record):López, A., Mestres, G., Karlsson Ott, M., Engqvist, H., Ferguson, S. et al. (2014) Compressive mechanical properties and cytocompatibility of bone-compliant, linoleic acidmodified bone cement in a bovine model. Journal of The Mechanical AbstractAdjacent vertebral fractures are a common complication experienced by osteoporosis patients shortly after vertebroplasty. Whether these fractures are due to the bone cement properties, the cement filling characteristics or to the natural course of the disease is still unclear. However, some data suggests that such fractures might occur because of an imbalance in the load distribution due to a mismatch between the elastic modulus (E) of the bonecement composite, and that of the vertebral cancellous bone. In this study, the properties of bone-compliant linoleic acid-modified bone cements were assessed using a bovine vertebroplasty model. Two groups of specimens (cementonly and bone-cement composites), and four subgroups comprising bone cements with elastic moduli in the range of 870-3500 MPa were tested to failure in uniaxial compression. In addition, monomer release as well as time and concentration-dependent cytocompatibility was assessed through the cement extracts using a Saos-2 cell model.Composites augmented with bone-compliant cements exhibited a reduction in E despite of their relatively high bone volume fraction (BVF). Moreover, a significant positive correlation between the BVF and E for the composites augmented with 870 MPa modulus cements was found. This was attributed to the increased relative contribution of the bone to the mechanical properties of the composites with a decrease in E of the bone cement. The use of linoleic acid reduced monomer conversion resulting in six times more monomer released after 24 hours. However, the cytocompatibility of the bone-compliant cements was comparable to that of the unmodified cements after the extracts were diluted four times. This study represents an important step towards introducing viable bone-compliant bone cements into vertebroplasty practice.
One of the major issues with the currently available injectable biomaterials for hard tissue replacement is the mismatch between their mechanical properties and those of the surrounding bone. Hybrid bone cements that combine the benefits of tough polymeric and bioactive ceramic materials could become a good alternative. In this work, polyhedral oligomeric silsesquioxane (POSS) was copolymerized with poly(ethylene glycol) (PEG) to form injectable in situ cross-linkable hybrid cements. The hybrids were characterized in terms of their mechanical, rheological, handling and in vitro bioactive properties. The results indicated that hybridization improves the mechanical and bioactive properties of POSS and PEG. The Young moduli of the hybrids were lower than those of commercial cements and more similar to those of cancellous bone. Furthermore, the strength of the hybrids was similar to that of commercial cements. Calcium deficient hydroxyapatite grew on the surface of the hybrids after 28 days in PBS, indicating bioactivity. The study showed that PEG–POSS-based hybrid materials are a promising alternative to commercial bone cements.
Acrylic bone cements have an elastic modulus several times higher than the surrounding trabecular bone. This has been hypothesized to contribute to certain clinical complications. There are indications that the addition of specific fatty acids and triglyceride oils may reduce the elastic modulus of these types of cements. Some of these additives also appear to have inherent antibiotic properties, although this has never been evaluated in bone cements. In this study, several types of fatty acids and triglyceride oils were evaluated for use in acrylic bone cements. Their mechanical properties were evaluated under uniaxial compression testing and selected cements were then further characterized in terms of microstructure, handling and antibacterial properties using scanning electron microscopy, polymerization temperature measurements, agar diffusion tests and bactericidal activity assays of cement extracts.It was found that any of the evaluated fatty acids or triglyceride oils could be used to tailor the stiffness of acrylic bone cements, although at varying concentrations, which also depended on the type of commercial base cement used. In particular, the addition 2 of very small amounts of linoleic acid (<2.0 wt%) resulted in Young's moduli and compressive strengths in the range of human trabecular bone, while maintaining a similar setting time. Further, the addition of 12.6 wt% ricinoleic acid to Osteopal V cement was found to have a significant antibacterial effect, inhibiting growth of Staphylococcus aureus in an agar diffusion test as well as demonstrating 100% bactericidal activity against the same strain.
Degeneration of the intervertebral disk constitutes one of the major causes of low back pain in adults aged 20-50 years old. In this study, injectable, in situ setting, degradable composites aimed for intervertebral disk replacement were prepared. β-TCP and calcium carbonate particles were mixed into acrylic-terminated oligo[D,L-lactide-co-(ε-caprolactone)], which were crosslinked at room temperature. The structure of the oligomers was confirmed by 1H-NMR spectroscopy. The composites were examined via SEM, and the mechanical properties of the crosslinked networks were determined. The porous β-TCP particles showed good mechanical anchorage to the matrix due to polymer penetration into the pores. In vitro degradation tests showed that the composites containing β-TCP slowly degraded, whereas the composites containing CaCO3 exhibited apatite formation capacity. It was concluded that the surface area, morphology, and solubility of the fillers might be used to control the degradation properties. The incorporation of fillers also increased both the elastic modulus and the maximum compression strength of the composites, properties that were similar to those of the physiological disk. These materials have potential for long-term intervertebral disk replacement and regenerative scaffolds because of their low degradation rates, bioactivity, and mechanical properties.
High radiopacity is required to monitor the delivery and positioning of injectable implants. Inorganic nonsoluble radiopacifiers are typically used in nondegradable bone cements; however, their usefulness in resorbable cements is limited due to their low solubility. Strontium halides, except strontium fluoride, are ionic water-soluble compounds that possess potential as radiopacifiers. In this study, we compare the radiopacity, mechanical properties, composition, and cytotoxicity of radiopaque brushite cements prepared with strontium fluoride (SrF 2 ), strontium chloride (SrCl 2 Á6H 2 O), strontium bromide (SrBr 2 ), or strontium iodide (SrI 2 ). Brushite cements containing 10 wt % SrCl 2 Á6H 2 O, SrBr 2 , or SrI 2 exhibited equal to or higher radiopacity than commercial radiopaque cements. Furthermore, the brushite crystal lattice in cements that contained the ionic radiopacifiers was larger than in unmodified cements and in cements that contained SrF 2 , indicating strontium substitution. Despite the fact that the strontium halides increased the solubility of the cements and affected their mechanical properties, calcium phosphate cements containing SrCl 2 Á6H 2 O, SrBr 2 , and SrI 2 showed no significant differences in Saos-2 cell viability and proliferation with respect to the control. Strontium halides: SrCl 2 Á6H 2 O, SrBr 2 , and SrI 2 may be potential candidates as radiopacifiers in resorbable biomaterials although their in vivo biocompatibility, when incorporated into injectable implants, is yet to be assessed.
Ceramic coatings may be applied onto metallic components of joint replacements for improved wear and corrosion resistance as well as enhanced biocompatibility, especially for metal-sensitive patients. Silicon nitride (SiNx) coatings have recently been developed for this purpose. To achieve a high coating density, necessary to secure a long-term performance, is however challenging, especially for sputter deposited SiNx coatings, since these coatings are insulating. This study investigates the time-dependent performance of sputter-deposited SiNx based coatings for joint applications. SiNx coatings with a thickness in the range of 4.3–6.0 µm were deposited by reactive high power impulse magnetron sputtering onto flat discs as well as hip heads made of CoCrMo. SiNx compositional analysis by X-ray photoelectron spectroscopy showed N/Si ratios between 0.8 and 1.0. Immersion of the flat disks in fetal bovine serum solution over time as well as short-term wear tests against ultra-high molecular weight polyethylene (UHMWPE) discs showed that a high coating density is required to inhibit tribocorrosion. Coatings that performed best in terms of chemical stability were deposited using a higher target power and process heating.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.