We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to protons cm−2 and protons cm−2 respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be and the damage constant for diamond irradiated with 800 MeV protons to be . Moreover, we observe the pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
Abstract-In this work we propose a new combined TCAD radiation damage modelling scheme, featuring both bulk and surface radiation damage effects, for the analysis of silicon detectors aimed at the High Luminosity LHC. In particular, a surface damage model has been developed by introducing the relevant parameters (NOX, NIT) extracted from experimental measurements carried out on p-type substrate test structures after gamma irradiations at doses in the range 10-500 Mrad(Si). An extended bulk model, by considering impact ionization and deep-level cross-sections variation, was included as well. The model has been validated through the comparison of the simulation findings with experimental measurements carried out at very high fluences (2×10 16 1 MeV equivalent n/cm 2 ) thus fostering the application of this TCAD approach for the design and optimization of the new generation of silicon detectors to be used in future HEP experiments.
The CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013–2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.
The upgrade of the LHC to the High-Luminosity LHC (HL-LHC) is expected to increase the LHC design luminosity by an order of magnitude. This will require silicon tracking detectors with a significantly higher radiation hardness. The CMS Tracker Collaboration has conducted an irradiation and measurement campaign to identify suitable silicon sensor materials and strip designs for the future outer tracker at the CMS experiment. Based on these results, the collaboration has chosen to use n-in-p type silicon sensors and focus further investigations on the optimization of that sensor type. This paper describes the main measurement results and conclusions that motivated this decision.
BackgroundIon Sensitive Field Effect Transistors (ISFETs) are one of the primitive structures for the fabrication of biosensors (BioFETs). Aiming at the optimization of the design and fabrication processes of BioFETs, the correlation between technological parameters and device electrical response can be obtained by means of an electrical device-level simulation. In this work we present a numerical simulation approach to the study of ISFET structures for bio-sensing devices (BioFET) using Synopsys Sentaurus Technology Computer-Aided Design (TCAD) tools.MethodsThe properties of a custom-defined material were modified in order to reproduce the electrolyte behavior. In particular, the parameters of an intrinsic semiconductor material have been set in order to reproduce an electrolyte solution.By replacing the electrolyte solution with an intrinsic semiconductor, the electrostatic solution of the electrolyte region can therefore be calculated by solving the semiconductor equation within this region.ResultsThe electrostatic behaviour (transfer characteristics) of a general BioFET structure has been simulated when the captured target number increases from 1 to 10. The ID current as a function of the VDS voltage for different positions of a single charged block and for different values of the reference electrode have been calculated.The electrical potential distribution along the electrolyte-insulator-semiconductor structure has been evaluated for different molar concentrations of the electrolyte solution.ConclusionsWe presented a numerical simulation approach to the study of Ion-Sensitive Field Effect Transistor (ISFET) structures for biosensing devices (BioFETs) using the Synopsys Sentaurus Technology Computer-Aided Design (TCAD) tools.A powerful framework for the design and optimization of biosensor has been devised, thus helping in reducing technology development time and cost. The main finding of the analysis of a general reference BioFET shows that there is no linear relationship between the number of charges and the current modulation. Actually, there is a strong position dependent effect: targets localized near the source region are most effective with respect to targets localized near the drain region. In general, even randomly distributed targets are more efficient with respect to locally grouped targets on the current modulation. Moreover, for the device at hand, a small positive biasing of the electrolyte solution, providing that the transistor goes on, will result in a greater enhancement of the current levels, still retaining a good sensitivity but greatly simplifying the operations of a real device.
In this work we propose the application of an enhanced radiation damage model based on the introduction of deep level traps / recombination centers suitable for device level numerical simulation of silicon detectors at very high fluences (e.g. 2.0 × 10 16 1 MeV equivalent neutrons/cm 2 ). We present the comparison between simulation results and experimental data for p-type substrate structures in different operating conditions (temperature and biasing voltages) for fluences up to 2.2 × 10 16 neutrons/cm 2 . The good agreement between simulation findings and experimental measurements fosters the application of this modeling scheme to the optimization of the next silicon detectors to be used at HL-LHC.
The three-dimensional concept in particle detection is based on the fabrication of columnar electrodes perpendicular to the surface of a solid state radiation sensor. It permits to improve the radiation resistance characteristics of a material by lowering the necessary bias voltage and shortening the charge carrier path inside the material. If applied to a long-recognized exceptionally radiation-hard material like diamond, this concept promises to pave the way to the realization of detectors of unprecedented performances. We fabricated conventional and three-dimensional polycrystalline diamond detectors, and tested them before and after neutron damage up to 1.2 ×1016 cm−2, 1 MeV-equivalent neutron fluence. We found that the signal collected by the three-dimensional detectors is up to three times higher than that of the conventional planar ones, at the highest neutron damage ever experimented.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.