Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
Significance The automatic generation algorithm of optical coherence tomography (OCT) images based on generative adversarial networks (GAN) can generate a large number of simulation images by a relatively small number of real images, which can effectively improve the classification performance. Aim We proposed an automatic generation algorithm for retinal OCT images based on GAN to alleviate the problem of insufficient images with high quality in deep learning, and put the diagnosis algorithm toward clinical application. Approach We designed a generation network based on GAN and trained the network with a data set constructed by 2014_BOE_Srinivasan and OCT2017 to acquire three models. Then, we generated a large number of images by the three models to augment age‐related macular degeneration (AMD), diabetic macular edema (DME), and normal images. We evaluated the generated images by subjective visual observation, Fréchet inception distance (FID) scores, and a classification experiment. Results Visual observation shows that the generated images have clear and similar features compared with the real images. Also, the lesion regions containing similar features in the real image and the generated image are randomly distributed in the image field of view. When the FID scores of the three types of generated images are lowest, three local optimal models are obtained for AMD, DME, and normal images, indicating the generated images have high quality and diversity. Moreover, the classification experiment results show that the model performance trained with the mixed images is better than that of the model trained with real images, in which the accuracy, sensitivity, and specificity are improved by 5.56%, 8.89%, and 2.22%. In addition, compared with the generation method based on variational auto‐encoder (VAE), the method improved the accuracy, sensitivity, and specificity by 1.97%, 2.97%, and 0.99%, for the same test set. Conclusions The results show that our method can augment the three kinds of OCT images, not only effectively alleviating the problem of insufficient images with high quality but also improving the diagnosis performance.
Significance The automatic generation algorithm of optical coherence tomography (OCT) images based on generative adversarial networks (GAN) can generate a large number of simulation images by a relatively small number of real images, which can effectively improve the classification performance. Aim We proposed an automatic generation algorithm for retinal OCT images based on GAN to alleviate the problem of insufficient images with high quality in deep learning, and put the diagnosis algorithm toward clinical application. Approach We designed a generation network based on GAN and trained the network with a data set constructed by 2014_BOE_Srinivasan and OCT2017 to acquire three models. Then, we generated a large number of images by the three models to augment age‐related macular degeneration (AMD), diabetic macular edema (DME), and normal images. We evaluated the generated images by subjective visual observation, Fréchet inception distance (FID) scores, and a classification experiment. Results Visual observation shows that the generated images have clear and similar features compared with the real images. Also, the lesion regions containing similar features in the real image and the generated image are randomly distributed in the image field of view. When the FID scores of the three types of generated images are lowest, three local optimal models are obtained for AMD, DME, and normal images, indicating the generated images have high quality and diversity. Moreover, the classification experiment results show that the model performance trained with the mixed images is better than that of the model trained with real images, in which the accuracy, sensitivity, and specificity are improved by 5.56%, 8.89%, and 2.22%. In addition, compared with the generation method based on variational auto‐encoder (VAE), the method improved the accuracy, sensitivity, and specificity by 1.97%, 2.97%, and 0.99%, for the same test set. Conclusions The results show that our method can augment the three kinds of OCT images, not only effectively alleviating the problem of insufficient images with high quality but also improving the diagnosis performance.
No abstract
No abstract
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.