2018
DOI: 10.1063/1.5029902
|View full text |Cite
|
Sign up to set email alerts
|

Zika virus detection using antibody-immobilized disposable cover glass and AlGaN/GaN high electron mobility transistors

Abstract: Zika virus detection was demonstrated using antibody-functionalized cover glasses externally connected to the gate electrode of an AlGaN/GaN high electron mobility transistor (HEMT). A pulsed bias voltage of 0.5 V was applied to an electrode on the region of the cover glass region functionalized with antibody, and the resulting changes of drain current of the HEMT were employed to determine the presence of Zika virus antigen concentration ranging from 0.1 to 100 ng/ml. The dynamic and static drain current chan… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 31 publications
(19 citation statements)
references
References 31 publications
(33 reference statements)
0
19
0
Order By: Relevance
“…This strategy was successful enough to spot down to 47.8 aM of the target biomolecules [ 111 ]. The efficiency of these investigations and many others [ 89 , 91 , 92 , 93 , 103 , 106 , 107 , 108 , 110 , 115 ] acknowledge the capability of FET-based immunosensors in detecting infectious diseases.…”
Section: Surface Modification and Functionalization Of Chem/biofetsmentioning
confidence: 98%
“…This strategy was successful enough to spot down to 47.8 aM of the target biomolecules [ 111 ]. The efficiency of these investigations and many others [ 89 , 91 , 92 , 93 , 103 , 106 , 107 , 108 , 110 , 115 ] acknowledge the capability of FET-based immunosensors in detecting infectious diseases.…”
Section: Surface Modification and Functionalization Of Chem/biofetsmentioning
confidence: 98%
“…Since 2015, nine papers were published on AlGaN/ GaN HEMT for the detection of biomarkers of different diseases: bacterial infection [61], Zika virus [64], prostate cancer [65,69], heart failure [66], mental stress [68] and DNA [62].…”
Section: Minireviewmentioning
confidence: 99%
“…24.1 shows the schematic of the sensor, consisting of an antibody-functionalized cover glass and an AlGaN/ GaN HEMT. Pulsed biasing of the electrode fabricated on the cover glass and functionalized with Zika antibody was used for detection [20]. The target Zika antigen (recombinant ZIKV NS1) solutions were diluted with bovine serum albumin (BSA) in pF 7.4 PBS solution with 0.1, 1, 10, or 100 ng/mL concentration.…”
Section: Zika Virusmentioning
confidence: 99%
“…The target Zika antigen (recombinant ZIKV NS1) solutions were diluted with bovine serum albumin (BSA) in pF 7.4 PBS solution with 0.1, 1, 10, or 100 ng/mL concentration. The reversible antigen and antibody binding through active sites on these two protein molecules and the HEMT drain current changes could fit with the Langmuir extension model [20]. In addition, the Hookean spring model was employed to simulate the relaxation portion of the time-dependent drain current.…”
Section: Zika Virusmentioning
confidence: 99%