1987
DOI: 10.1016/0168-9002(87)90770-4
|View full text |Cite
|
Sign up to set email alerts
|

X-ray focussing for synchrotron radiation microprobe analysis at the SRS, Daresbury (UK)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
4
0

Year Published

1989
1989
1994
1994

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…A tabulation of photon fluxes and spatial resolutions for sever- ft, = 10 cm ftm = 10 m Figure 2. Schematics showing different approaches used for a high-resolution X-ray microscope: (a) ellipsoidal mirror at NSLS (2), (b) LBL Kirkpatrick-Baez system using spherical multilayer surfaces and tested at NSLS (3), (c) Wolter focusing mirror system with combined ellipsoidal and hyperboloidal surfaces of revolution used at Photon Factory (4), and (d) bent crystal system used at Daresbury (5). The field of view on the TV monitor is 2-10 mm, and the optical resolution is about 10 fim.…”
Section: Types Of Xrf X-ray Microscopesmentioning
confidence: 99%
See 1 more Smart Citation
“…A tabulation of photon fluxes and spatial resolutions for sever- ft, = 10 cm ftm = 10 m Figure 2. Schematics showing different approaches used for a high-resolution X-ray microscope: (a) ellipsoidal mirror at NSLS (2), (b) LBL Kirkpatrick-Baez system using spherical multilayer surfaces and tested at NSLS (3), (c) Wolter focusing mirror system with combined ellipsoidal and hyperboloidal surfaces of revolution used at Photon Factory (4), and (d) bent crystal system used at Daresbury (5). The field of view on the TV monitor is 2-10 mm, and the optical resolution is about 10 fim.…”
Section: Types Of Xrf X-ray Microscopesmentioning
confidence: 99%
“…(4) measured a resolution of 10 X 30 with a Wolter-type mirror system, and Van Langevelde et al (5) obtained 30 ^m at the Daresbury synchrotron using a doubly bent Si crystal system. Thus the best resolutions obtained with the first generation of synchrotron microprobes are on the order of 10 jim or more.…”
Section: Spatial Resolution Of the Xrmmentioning
confidence: 99%
“…(4) measured a resolution of 10 X 30 μπι with a Wolter-type mirror system, and Van Langevelde et al (5) obtained 30 μπι at the Daresbury synchrotron using a doubly bent Si crystal system. Thus the best resolutions obtained with the first generation of synchrotron microprobes are on the order of 10 μπι or more.…”
Section: Spatial Resolution Of the Xrmmentioning
confidence: 99%
“…Schematics showing different approaches used for a high-resolution X-ray microscope: (a) ellipsoidal mirror at NSLS (2), (b) LBL Kirkpatrick-Baez system using spherical multilayer surfaces and tested at NSLS (3), (c) Wolter focusing mirror system with combined ellipsoidal and hyperboloidal surfaces of revolution used at Photon Factory (4), and (d) bent crystal system used at Daresbury(5).…”
mentioning
confidence: 99%