1999
DOI: 10.1016/s0029-5493(98)00319-7
|View full text |Cite
|
Sign up to set email alerts
|

X-ray computed laminography: an approach of computed tomography for applications with limited access

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
44
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 92 publications
(50 citation statements)
references
References 4 publications
0
44
0
Order By: Relevance
“…It had been developed into a computer tomography (CT) method (155), but this was rarely used. The increasing availability of synchrotron X-ray sources, however, may change this in the future (139,156).…”
Section: Penetrating Radiation Test Methodsmentioning
confidence: 99%
“…It had been developed into a computer tomography (CT) method (155), but this was rarely used. The increasing availability of synchrotron X-ray sources, however, may change this in the future (139,156).…”
Section: Penetrating Radiation Test Methodsmentioning
confidence: 99%
“…In addition, local tomography with limited angle range delivers an image with anisotropic resolution. Reference [8] points out the fact that limited angle range tomography is equivalent to laminography, and the samples presented there clearly show the anisotropic resolution and distorted representation of cracks. Figure 2 shows an area of 27 × 27 mm 2 (cell 52) that has been found to be representative for the whole cell.…”
Section: Radiography and Local Tomography Of A Nio-ysz Pelletmentioning
confidence: 98%
“…Applications featuring flat samples, where one dimension is much smaller than others, include finding defects in microchips, rotor blades for wind energy plants, or the analysis of fossils, where samples must not be destroyed. Especially for these areas of application, where CT has severe drawbacks, a technique called Computed Laminography (CL) has been developed [1][2][3][4][5][6]. Hereby, X-ray images are generated using a specific geometry like the CLARA setup [3,7].…”
Section: P Trampert Et Al / Spherically Symmetric Volume Elements Amentioning
confidence: 99%
“…Especially for these areas of application, where CT has severe drawbacks, a technique called Computed Laminography (CL) has been developed [1][2][3][4][5][6]. Hereby, X-ray images are generated using a specific geometry like the CLARA setup [3,7]. In this setup, X-ray source and detector are initially rotated by a fixed angle around the horizontal rotation axis (z-axis).…”
Section: P Trampert Et Al / Spherically Symmetric Volume Elements Amentioning
confidence: 99%