2004
DOI: 10.1023/b:janc.0000037280.30012.26
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Determination of Sulfide Ions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 1 publication
0
5
0
Order By: Relevance
“…Metal complexation measurements were performed via voltammetry (Rozan et al, 1999;Kovaleva, 2004;Andjelkovic, 2006). An AIS Model DLK-100A Electrochemical Analyzer Rev 3.3 was used to the determine complexation capacity of metals with DOM.…”
Section: Dom-metal Complexation Measurementsmentioning
confidence: 99%
“…Metal complexation measurements were performed via voltammetry (Rozan et al, 1999;Kovaleva, 2004;Andjelkovic, 2006). An AIS Model DLK-100A Electrochemical Analyzer Rev 3.3 was used to the determine complexation capacity of metals with DOM.…”
Section: Dom-metal Complexation Measurementsmentioning
confidence: 99%
“…Furthermore, the obtained Pt-NCs showed a selective response to S 2− over other competitive anions in buffer solutions, and could be used as a specific sensor for S 2− detection. In comparison to other strategies developed for S 2− detection [38][39][40][41][42][43], the present study has its obvious advantages as it is highly sensitive, rapid, simple, cost-effective and non-polluting. Therefore, the present study reports a 'green-synthesis' method, which is performed in one step, and is cost-effective, non-cytotoxic and bioapplicable, and particularly requires a short reaction time for the synthesis of BSA-protected, highly fluorescent Pt-NCs, which could be extended to other kinds of protein-protected Pt-NCs.…”
Section: Discussionmentioning
confidence: 99%
“…Overinhalation of sulfide can irritate mucous membranes, and cause unconsciousness and respiratory paralysis. Thus, the detection of sulfide has become particularly important for industrial, environmental and biological research, and other related fields [38][39][40][41][42][43]. The prepared Pt-NCs@BSA are then applied to the detection of S 2− in HEPES buffer solutions (10 mM, pH=7.4).…”
Section: Detection Of Sulfide Ions (S 2−mentioning
confidence: 99%
“…Briefly, nitrogen gas was bubbled through a vessel containing a sediment sample in 1 N HCl for forty-five minutes and the off gases were captured in two traps containing NaOH. Sulfide was measured voltammetrically (AIS DLK 100A) using a thin film mercury electrode in conjunction with a silver/silver chloride reference electrode, and platinum counter electrode (Kovaleva, 2004). AVS Simultaneously Extractable Metals (AVS/SEM) were measured after filtering the acidified sample with a 0.45 um filter and measuring metals using AAS.…”
Section: Sediment Analysismentioning
confidence: 99%