Voltage stability monitoring using a modified thevenin impedance

Abstract: -This paper presents a method for voltage stability monitoring based on the maximum power transfer to the load. The only required information is the system topology, the data from PMUs and the operational status of synchronous generators. With this information, the Thevenin impedance seen from a load bus can be estimated and by using the Thevenin theorem for maximum power transfer an impedance based stability index can be established. Since the Thevenin impedance is influenced by the operational conditions of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
2
0
2

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 10 publications
0
2
0
2
Order By: Relevance
“…Güç sisteminde ilgili bara arkasında kalan güç sisteminin Thevenin eşdeğeri bilindiği takdirde baradan çekebilecek maksimum güç, maksimum güç transferi yasası ile hesaplanabilir. Yük empedansının (ZYük), Thevenin empedansına (ZTh) eşit olduğu durumda yüke transfer edilebilecek görünür güç maksimum olur [21]. Şekil 3'deki yüke transfer edilecek gücün empedansa göre değişimi grafik olarak verilmiştir.…”
Section: Maksi̇mum Güç Transferi̇ Ve Geri̇li̇m Kararlilik İndeksi̇unclassified
“…Güç sisteminde ilgili bara arkasında kalan güç sisteminin Thevenin eşdeğeri bilindiği takdirde baradan çekebilecek maksimum güç, maksimum güç transferi yasası ile hesaplanabilir. Yük empedansının (ZYük), Thevenin empedansına (ZTh) eşit olduğu durumda yüke transfer edilebilecek görünür güç maksimum olur [21]. Şekil 3'deki yüke transfer edilecek gücün empedansa göre değişimi grafik olarak verilmiştir.…”
Section: Maksi̇mum Güç Transferi̇ Ve Geri̇li̇m Kararlilik İndeksi̇unclassified
“…In [12] the activation of overexcitation limiters (OXLs) is anticipated to more accurately determine the maximum deliverable power to the load. In [13] one of four possible operating states of a generator is modelled as an impedance and included in the network to determine the MPT to the load. The four states are; no limits have been reached, the OXL or the armature current limiter are activated or in case the generator injects maximum active power.…”
Section: Introductionmentioning
confidence: 99%
“…Três diferentes metodologias são comumente utilizadas para monitor a margem de estabilidade de tensão com PMUs: métodos baseadas no teorema de Thévenin, aquelas baseadas em Redes Neurais Artificiais eíndices de estabilidade de tensão. Gong et al (2006), Corsi and Taranto (2008), Mou et al (2012), Su and Liu (2016) e Polster et al (2017) utilizaram o equivalente de Thévenin, calculado a partir de medidas de PMU, para avaliar a estabilidade de tensão em tempo real.…”
Section: Introductionunclassified