2009
DOI: 10.1109/tie.2008.2009195
|View full text |Cite
|
Sign up to set email alerts
|

Voltage-Balance Compensator for a Carrier-Based Modulation in the Neutral-Point-Clamped Converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
64
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 145 publications
(64 citation statements)
references
References 20 publications
0
64
0
Order By: Relevance
“…In [14], a similar solution for NTV 2 modulation has the same flaws as [9]. An optimized NTV 2 (ONTV 2 ) PWM with closed-loop control [15] can also comprehensively achieve this objective. However, the design of the closed-loop control scheme interfacing the ONTV 2 PWM is not straight forward and this type of compensators does not take into account the instantaneous values of the output currents [16].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In [14], a similar solution for NTV 2 modulation has the same flaws as [9]. An optimized NTV 2 (ONTV 2 ) PWM with closed-loop control [15] can also comprehensively achieve this objective. However, the design of the closed-loop control scheme interfacing the ONTV 2 PWM is not straight forward and this type of compensators does not take into account the instantaneous values of the output currents [16].…”
Section: Introductionmentioning
confidence: 99%
“…However, the design of the closed-loop control scheme interfacing the ONTV 2 PWM is not straight forward and this type of compensators does not take into account the instantaneous values of the output currents [16]. A double-signal pulse width modulation (DSPWM) based on carrier-based modulation using two modulation signals per phase was proposed in [15]. The DSPWM has the same effect as the NTV 2 .…”
Section: Introductionmentioning
confidence: 99%
“…There are some modulation techniques that are able to completely eliminate the oscillations in NPP [5][6][7]. In [8] a dynamic limiter and a control loop are presented that provide the system with a fast balancing dynamic and guarantee stability under the all operating conditions. Also there are several nonlinear control methods [9][10] to maintain the output voltages balance.…”
Section: Introductionmentioning
confidence: 99%
“…Other experts have done research on topologies and control strategies utilizing low-voltage DVRs with a three-phase three-wire [6] or a three-phase four-wire [7]. High-voltage DVRs with the neutral-point clamped type [8], flying capacitor type [9] or cascaded type [10] have also been studied. Currently, the industrial application of DVRs is mainly in low-voltage.…”
Section: Introductionmentioning
confidence: 99%