Virtual prototyping of a new intramedullary nail for tibial fractures

Abstract: In this work a new distal interlocking system has been developed which is easy to use, allows a reduction of the operating time and consequently the exposure to radiations both for surgeon and patient. The main goal of this study has been the design of a new intramedullary nail for tibial fractures able to simplify and speed up the distal locking operation phases. After a preliminary stage during which several candidate concepts have been proposed and analysed, the best solution has been developed and deeply i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
5
4

Relationship

1
8

Authors

Journals

citations
Cited by 12 publications
(8 citation statements)
references
References 16 publications
0
6
0
1
Order By: Relevance
“…To verify the structural strength of the prototype [26,27], biomechanical FEM analyses have been executed [3,28,29]. These FEM analyses were carried out only on the structural parts of the orthosis.…”
Section: Fem Analysesmentioning
confidence: 99%
“…To verify the structural strength of the prototype [26,27], biomechanical FEM analyses have been executed [3,28,29]. These FEM analyses were carried out only on the structural parts of the orthosis.…”
Section: Fem Analysesmentioning
confidence: 99%
“…This improvement also allowed an extension of the indication for intramedullary nail beyond shaft fracture cases. This invention also does not interfere with the vascularization of the fractured region; it creates an adequate environment to treat the fracture, permit full function, and most importantly allow patients early mobilization, which consequently accelerates the healing process …”
Section: The Evolutionary Biomechanical Landmarksmentioning
confidence: 99%
“…This invention also does not interfere with the vascularization of the fractured region; it creates an adequate environment to treat the fracture, permit full function, and most importantly allow patients early mobilization, which consequently accelerates the healing process. [22][23][24] In the early 1980s, there was an awareness of the benefits of replacing slotted nail designs with nonslotted ones. This important decision was made on the basis of the limitations identified in the slotted design, such as the low torsional strength of the implant and the fragility of the stress concentration zone (i.e., the transition zone between the nonslotted and slotted portions, which is characterized by material thickness variation).…”
Section: The Evolutionary Biomechanical Landmarksmentioning
confidence: 99%
“…Per individuare la sezione con i valori più elevati (di trazione e compressione) di deformazione sulla quale installare gli estensimetri, si è preliminarmente eseguita una simulazione numerica impiegando un codice di calcolo agli elementi finiti (Ansys Workbench), largamente utilizzato in svariati settori come il biomeccanico [5], quello della sicurezza passiva [6][7][8], la caratterizzazione e ottimizzazione dei materiali compositi. Nel presente lavoro, al fine di semplificare il processo di simulazione numerica, senza però inficiare l'attendibilità dei risultati, sono stati utilizzati modelli FEM semplificati.…”
Section: Procedura Numericaunclassified