Virtual non-contrast in second-generation, dual-energy computed tomography: Reliability of attenuation values

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

10
80
2

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
3

Relationship

1
9

Authors

Journals

citations
Cited by 146 publications
(92 citation statements)
references
References 20 publications
10
80
2
Order By: Relevance
“…These were the greatest in the aorta, spleen, and fat; although present, the differences were below 15 HU in 95.5% of measurements. 37 Larger differences between the virtual and true unenhanced HU in the spleen and fat compared with other abdominal organs were also noted on portal-phase DSDE with the use of a tin filter on DSDE. 38 With the introduction of a new RSDE postprocessing material suppression technique called GSI VUE (General Electric Healthcare, Waukesha, WI) that uses a multimaterial decomposition to quantify then replace iodine fractional values with blood to create a monoenergetic image on which HUs are measurable, there is now capability to compare virtual unenhanced HU to conventional unenhanced HU on this scanner as well.…”
Section: Dual-energy Ct Evaluation Of Hepatic Fat Contentmentioning
confidence: 88%
“…These were the greatest in the aorta, spleen, and fat; although present, the differences were below 15 HU in 95.5% of measurements. 37 Larger differences between the virtual and true unenhanced HU in the spleen and fat compared with other abdominal organs were also noted on portal-phase DSDE with the use of a tin filter on DSDE. 38 With the introduction of a new RSDE postprocessing material suppression technique called GSI VUE (General Electric Healthcare, Waukesha, WI) that uses a multimaterial decomposition to quantify then replace iodine fractional values with blood to create a monoenergetic image on which HUs are measurable, there is now capability to compare virtual unenhanced HU to conventional unenhanced HU on this scanner as well.…”
Section: Dual-energy Ct Evaluation Of Hepatic Fat Contentmentioning
confidence: 88%
“…The low tube current of only 80 kV brings an inappropriate photon rate to the detectors in the abdomen and results in a low penetration depth and artifacts (26). With the novel technology of a tin filter for the 140-kV tube voltage, the x-ray spectra overlap between 100 kV and Sn140 kV is reduced (27,28). We scanned the spine with 100-and Sn140-kV tube voltages to reduce the artifacts, especially in patients with a large body mass index.…”
Section: Musculoskeletal Imaging: Bone Marrow Edema In Vertebral Compmentioning
confidence: 99%
“…Dual-energy CT (DECT) can obtain different energy data to differentiate between various substances [12,13], which allows the removal of calcium from the resultant image. Virtual non-calcium (VNCa) image of the bone joint can display the bone marrow by means of subtracting of calcium using dual-energy algorithm [14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%