IEEE Nuclear Science Symposium Conference Record, 2005
DOI: 10.1109/nssmic.2005.1596876
|View full text |Cite
|
Sign up to set email alerts
|

Variance Reduction on Randoms from Delayed Coincidence Histograms for the HRRT

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
46
0

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(47 citation statements)
references
References 10 publications
0
46
0
Order By: Relevance
“…The datasets were also binned (using span 9) and reconstructed using the OP-OSEM algorithm. The scatter sinograms were estimated using the single-scatter simulation method (22), and random sinograms were derived from smoothed delayed-coincidence window data (23).…”
Section: Noise and Contrast Recovery Characterizationmentioning
confidence: 99%
“…The datasets were also binned (using span 9) and reconstructed using the OP-OSEM algorithm. The scatter sinograms were estimated using the single-scatter simulation method (22), and random sinograms were derived from smoothed delayed-coincidence window data (23).…”
Section: Noise and Contrast Recovery Characterizationmentioning
confidence: 99%
“…3D-OSWLS showed accuracy in patient studies similar to that of 3D-FBP (21) but resulted in a much lower pixel variance. For all HRRT reconstructions, randoms were estimated by the variance reduction on randoms algorithm (23,25). All HRRT-reconstructed images were also postsmoothed with a 6-mm FWHM gaussian kernel to match image resolution with that of the HR1 scanner.…”
Section: Reconstructionsmentioning
confidence: 99%
“…During emission scanning, continuous online arterial blood sampling was performed (26). At set times (5,10,15,20,30,40, and 60 min after injection), continuous blood sampling was interrupted to collect manual blood samples. These manual sample data were used for calibrating the (online) blood sampler, for measuring plasma or whole-blood ratios, and for determining metabolite fractions (27).…”
Section: Phantoms and Studiesmentioning
confidence: 99%
“…A 3-dimensional (3D) attenuation and normalization weighted ordered-subsets expectation maximization (ANW-OSEM) reconstruction method showed considerable bias for a homogeneous phantom (4). Therefore, a 3D ordinary Poisson OSEM (OP-OSEM) reconstruction method was implemented that showed considerably less bias, especially when randoms were estimated by the variance reduction on a randoms (VRR) algorithm (5). However, bias was still encountered for shortduration (5-60 s) frames (6,7).…”
mentioning
confidence: 99%