2020
DOI: 10.1016/j.fuproc.2020.106512
|View full text |Cite
|
Sign up to set email alerts
|

Validation and application of CPFD model in simulating gas-solid flow and combustion of a supercritical CFB boiler with improved inlet boundary conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 42 publications
0
10
0
Order By: Relevance
“…There are three furnace outlets at one side of the 600 MW CFB boiler, and each outlet corresponds to two returning ports. The flow rate of each circulation loop was determined by our previous experimental and calculated results [17]. Simulations in this study were performed with Ansys FLUENT.…”
Section: Computational Mesh and Solution Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…There are three furnace outlets at one side of the 600 MW CFB boiler, and each outlet corresponds to two returning ports. The flow rate of each circulation loop was determined by our previous experimental and calculated results [17]. Simulations in this study were performed with Ansys FLUENT.…”
Section: Computational Mesh and Solution Methodsmentioning
confidence: 99%
“…In particular, the standard deviations of the lateral diffusion distance of the IUSA and ILSA increased nearly three times under the non-uniform SA condition. The reason is that the solid concentration on the inclined wall of the pent-leg furnace is higher than that on the outer wall [17], so changes of SA velocity distribution have a greater impact on the gas lateral diffusion.…”
Section: Influence Of Sa Uniformity On Jet Penetration and Diffusionmentioning
confidence: 99%
See 1 more Smart Citation
“…The Ecom-J2KN type analyzer was for routine use, while the Testo 350 type analyzer would be used in the areas with odd values or large concentration gradients as a check. According to our experience of on-site tests, the gas composition would still show sinusoidal fluctuation under stable loads [32,33], so at least two groups of peak/valley values of flue gas should be recorded. As the height of the horizontal flue pass was 10 m and the ash deposition layer at the bottom was about 2-3 m, the maximum penetration depth of 7 m could basically cover the flow area of the SNCR inlets.…”
Section: Measurement Port Arrangement and Test Proceduresmentioning
confidence: 99%
“…The CFD models can be used for complex analysis of multi-fuel CFB (circulating fluidized bed) unit operation concepts [ 6 , 7 , 8 , 9 ]. Various 3D-CFB models can be found in the literature [ 10 , 11 , 12 , 13 , 14 , 15 ], some of which consider the multi-fuel, CFB concept; however, the use of gaseous fuel, with a properly organized gas supply system, cannot be found in said literature. Such an idea may be beneficial for a power unit’s flexibility and provides the stable operation of a boiler furnace with a substantial demand reduction in its capacity.…”
Section: Introductionmentioning
confidence: 99%