Since the adsorption chillers do not use primary energy as driving source the possibility to employ low temperature waste heat sources in cooling energy production receives nowadays much attention of the industry and science community. However, the performance of the thermally driven adsorption systems is lower than that of other heat driven heating/cooling systems. Low coefficients of performance are one of the main disadvantages of adsorption coolers. It is the result of a poor heat transfer coefficient between the bed and the immersed heating surfaces of a built-in heat exchanger system. The purpose of this work is to study the effect of thermal conductance values of sorption elements and evaporator as well as other design parameters on the performance of a reheat two-stage adsorption chiller. One of the main energy efficiency factors in cooling production, i. e. cooling capacity for wide-range of both design and operating parameters is analyzed in the paper. Moreover, the work introduces artificial intelligence approach for the optimization study of the adsorption cooler. The ANFIS was employed in the work. The increase in both the bed and evaporator conductance provides better performance of the considered innovative adsorption chiller. The highest obtained value of cooling capacity is 21.7 kW and it can be achieved for the following design and operational parameters of the considered reheat twostage adsorption chiller:
Energy efficiency is one of the most important topics nowadays. It is strictly related to energy demand, energy policy, environmental pollution, and economic issues. Energy efficiency can be increased and operating costs reduced by using waste heat from other processes. One of the possibilities is to use sorption chillers to produce chilled water and desalinated water. Low-temperature waste heat is not easy to utilize because of the low energy potential. Using adsorption chillers in low-temperature conditions allows utilizing waste heat and producing useful products in many regions of the world. The paper presents the results of an experimental study carried out on a three-bed adsorption chiller with desalination function, using silica gel and water as a working pair. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stands scheme and description were presented. All results were obtained during several test hours with stable temperature conditions in the range of 57–85 °C for the heating water. It is found that the Coefficient of Performance (COP) increased from 0.20 to 0.58 when the heating water temperature increased from 57 to 85 °C. A similar finding is reported for Specific Cooling Power (SCP), which increased from 27 to 160 W/kg as the heating water temperature increased from 57 to 85 °C. It can be concluded that the heating water temperature strongly impacts the performance of the adsorption chiller.
The demand for electricity is growing rapidly along with economic development and increasing population. At present, its production is mainly based on non-renewable sources, which has negative impacts on the environment and contributes to global warming. A large proportion of the produced electricity is consumed by refrigeration equipment. Climate change and the progress of civilisation are additionally increasing the demand for cooling, with increasing electricity consumption as a consequence. One of the options for obtaining eco-friendly cooling is the use of adsorption chillers. These devices are powered by low-temperature heat and their operation only requires a small amount of electrical energy. The source of low-temperature heat can be, e.g., waste heat generated in many industrial processes. Its use allows one to increase energy efficiency and achieve additional financial benefits. However, adsorption chillers are characterised by low coefficients of performance. This paper presents possibilities to improve their performance. It also presents the results of tests carried out on a three-bed adsorption chiller with desalination function. The aim of the investigation was to determine the effect of the cycle time on the coefficient of performance (COP) and specific cooling power (SCP). The working pair was silica gel and water. The results confirmed the effect of the duration of adsorption and desorption on the COP and SCP of the adsorption chiller. Increasing the duration of the cycle led to an increase in the COP.
Energy efficiency is one of the most important topics nowadays. It is strictly related to the problem of energy demand, energy policy, environmental pollution, and economic issues. Because of the technological development, using more advanced processes in almost every part of industry, and increasing demands both for a high standard of living and simplification of processes, the energy demand is growing. This can be observed, e.g., in the building sector – air conditioning is present in almost every new building and people expect high quality thermal conditions. Energy efficiency can be increased and operation costs reduced by using waste heat in other processes. One of the possibilities is to use sorption chillers to produce cool and desalinated water. The paper presents the results of experimental study carried out on three-bed adsorption chiller with desalination, using silica gel and water as the working pair. The chiller was equipped with plate-fin tube heat exchanger filled with silica gel with a grain size of 0.5-1.5 mm. The laboratory test stand included one evaporator, one condenser, and three separate tanks for water, desalinated water, and brine, respectively. The test stand scheme and description were presented. All results were obtained during a few hours test with stable temperature conditions in the range of: 55-85°C for the heating water.
Adsorption chillers can be a promising part of sustainable development concept of the global economy due to the utilization of low grade thermal energy sources for cooling production. Therefore, research aiming at improving their performance i.e. Coefficient of Performance (COP) by optimizing the heat and mass transfer condition in the adsorption beds are crucial. Innovative modification of the sorbent layer structure are proposed in the paper in order to improve the heat transfer characteristics in the heat exchanger boundary layer. The analysis of desorption conditions in the parametric model of a coated adsorption bed construction is presented in the paper. The computational fluid dynamics with conjugate heat transfer analysis are used to determine the crucial input parameters for further analytical calculations. The heat transfer condition in novel coated design and a conventional fixed bed are compared in the paper. The developed computational model consisted of three subdomains representing heating water, heat exchanger material (copper) and sorbent (silica gel).
A distinct advantage of adsorption chillers is their ability to be driven by heat of near ambient temperature. However the performance of the thermally driven adsorption systems is lower than that of other heat driven heating/cooling systems. It is the result of a poor heat transfer coefficient between the bed and the immersed heating surfaces of a built-in heat exchanger system. The aim of this work is to study the effect of thermal conductance values as well as other design parameters on the performance of a re-heat two-stage adsorption chiller. One of the main energy efficiency factors in cooling production, i.e. cooling capacity (CC) for wide-range of both design and operating parameters is analyzed in the paper. Moreover, the work introduces artificial intelligence (AI) approach for the optimization study of the adsorption cooler. The Adaptive Neuro – Fuzzy Inference System (ANFIS) was employed in the work. The developed ANFIS model can be applied for optimizations purposes and may constitute a submodel or a separate module in engineering calculations, capable to predict the CC of the re-heat two-stage adsorption chiller.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.